Your browser doesn't support javascript.
loading
Aortic arch aneurysm repair - Unsteady hemodynamics and perfusion at different heart rates.
Steinlauf, Shirly; Hazan Shenberger, Sapir; Halak, Moshe; Liberzon, Alex; Avrahami, Idit.
Afiliação
  • Steinlauf S; Department of Mechanical Engineering and Mechatronics, Ariel University, Israel; School of Mechanical Engineering, Tel Aviv University, Tel Aviv 69978, Israel.
  • Hazan Shenberger S; Department of Mechanical Engineering and Mechatronics, Ariel University, Israel.
  • Halak M; Department of Vascular Surgery, the Chaim Sheba Medical Center, Tel Hashomer, Israel.
  • Liberzon A; School of Mechanical Engineering, Tel Aviv University, Tel Aviv 69978, Israel.
  • Avrahami I; Department of Mechanical Engineering and Mechatronics, Ariel University, Israel. Electronic address: IditAv@Ariel.ac.il.
J Biomech ; 121: 110351, 2021 05 24.
Article em En | MEDLINE | ID: mdl-33794471
The aortic arch aneurysm is a complex disease that requires branching of one or more aortic arch vessels and can be fatal if left untreated. In this in vitro study, we examine the effect of the treatment approach on the unsteady hemodynamics and blood perfusion to the upper vessel's in models of an aortic arch aneurysm, and of the three common repair approaches: open-chest surgical repair, chimney, and hybrid approach. A particle image velocimetry method was used to quantify the unsteady hemodynamics in the four models simulated in a mock circulatory loop, to evaluate unsteady hemodynamic parameters and measure perfusion to the brain and the upper body. According to the findings, in terms of perfusion to the brain and upper body, the surgery model has the highest flow rate comparing to the other models in most heart-rate conditions. It also shows oscillatory parameters in the upper vessels which in normal arteries are correlated with a better arterial function. Between the two endovascular procedures, the hybrid model exhibits slightly better hemodynamic characteristics than the chimney model, with lower shear stresses and more oscillatory flow and WSS in the upper vessels. The hybrid model had lower perfusion flow rates to upper vessels during rest conditions (90BPM). However, unlike the other models, perfusion in the hybrid model increased with heart rate, thus at 135 BPM, it results in flow rate to upper vessels similar to that of the chimney model. The results of this study may shed light on future endograft' design and placement techniques.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma Aórtico / Implante de Prótese Vascular / Procedimentos Endovasculares Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Biomech Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Israel País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma Aórtico / Implante de Prótese Vascular / Procedimentos Endovasculares Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Revista: J Biomech Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Israel País de publicação: Estados Unidos