Your browser doesn't support javascript.
loading
Electrochemical impedance biosensor for detection of saxitoxin in aqueous solution.
Serrano, Pablo C; Nunes, Gisele E; Avila, Lindiomar B; Reis, Carleane P S; Gomes, Aldo M C; Reis, Françoise T; Sartorelli, Maria L; Melegari, Silvia Pedroso; Matias, William G; Bechtold, Ivan H.
Afiliação
  • Serrano PC; Departamento de Física, Universidade Federal de Santa Catarina, Florianópolis, SC, 88040-900, Brazil.
  • Nunes GE; Departamento de Física, Universidade Federal de Santa Catarina, Florianópolis, SC, 88040-900, Brazil.
  • Avila LB; Departamento de Física, Universidade Federal de Santa Catarina, Florianópolis, SC, 88040-900, Brazil.
  • Reis CPS; Departamento de Física, Universidade Federal de Santa Catarina, Florianópolis, SC, 88040-900, Brazil.
  • Gomes AMC; Departamento de Física, Universidade Federal de Santa Catarina, Florianópolis, SC, 88040-900, Brazil.
  • Reis FT; Departamento de Física, Universidade Federal de Santa Catarina, Florianópolis, SC, 88040-900, Brazil.
  • Sartorelli ML; Departamento de Física, Universidade Federal de Santa Catarina, Florianópolis, SC, 88040-900, Brazil.
  • Melegari SP; Centro de Estudos do Mar, Universidade Federal do Paraná, Pontal do Paraná, PR, 83255-976, Brazil.
  • Matias WG; Departamento de Engenharia Sanitária e Ambiental, Universidade Federal de Santa Catarina, Florianópolis, SC, 88040-900, Brazil.
  • Bechtold IH; Departamento de Física, Universidade Federal de Santa Catarina, Florianópolis, SC, 88040-900, Brazil. ivan.bechtold@ufsc.br.
Anal Bioanal Chem ; 413(25): 6393-6399, 2021 Oct.
Article em En | MEDLINE | ID: mdl-34389880
Saxitoxin is a cyanotoxin which is very harmful to human health; the concentration limit in drinking water is only 3 µg/L. Therefore, a simple, fast, sensitive, low-cost, and specific method for its detection, quantification, and monitoring in water bodies is needed to avoid adverse effects on animal and human health. In this work, we developed an electrochemical impedimetric biosensor using a specific aptamer as recognition element for saxitoxin detection. This method allies the superior sensing characteristics of aptamers with the nondestructive, label-free, and easy working principles of the electrochemical impedance technique. The device presented sensitivity for detecting saxitoxin concentrations above 0.3 µg/L, with high selectivity in negative control experiments, demonstrating a promising alternative for water toxin detection.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha