Your browser doesn't support javascript.
loading
Chemometric tools in the optimization of a microwave-assisted digestion procedure for guarana-based drink samples and data analysis from elemental, caffeine, and epicatechin contents.
Cerqueira da Silva, Vinnícius Henrique; Sampaio da Silva Junior, André Luiz; Pinheiro Lôbo, Ivon; Galvao Paranhos da Silva, Erik; Almeida Bezerra, Marcos; Gonçalves Silva, Allison; da Silva Lima, Luciano; Mota de Jesus, Raildo.
Afiliação
  • Cerqueira da Silva VH; State University of Santa Cruz, Department of Exact and Technological Sciences, Research Group in Analytical Chemistry of Southern Bahia, Rodovia Ilhéus-Itabuna, km 16, 45662-900 Ilhéus, Bahia, Brazil.
  • Sampaio da Silva Junior AL; State University of Santa Cruz, Department of Exact and Technological Sciences, Research Group in Analytical Chemistry of Southern Bahia, Rodovia Ilhéus-Itabuna, km 16, 45662-900 Ilhéus, Bahia, Brazil.
  • Pinheiro Lôbo I; State University of Santa Cruz, Department of Exact and Technological Sciences, Research Group in Analytical Chemistry of Southern Bahia, Rodovia Ilhéus-Itabuna, km 16, 45662-900 Ilhéus, Bahia, Brazil.
  • Galvao Paranhos da Silva E; State University of Santa Cruz, Department of Exact and Technological Sciences, Research Group in Analytical Chemistry of Southern Bahia, Rodovia Ilhéus-Itabuna, km 16, 45662-900 Ilhéus, Bahia, Brazil.
  • Almeida Bezerra M; State University of Southwest Bahia, Jequié Campus, Department of Sciences and Technologies, Rua José Moreira Sobrinho s/n, Jequié, Bahia 45.208-091, Brazil.
  • Gonçalves Silva A; Federal Institute of Education, Science and Technology of Bahia - IFBA Porto Seguro, Rod. Br 367Km 57 5, Bairro Fontana I - CEP, 45810-000, Bahia, Brazil.
  • da Silva Lima L; Federal Institute of Education, Science and Technology of Bahia - IFBA Porto Seguro, Rod. Br 367Km 57 5, Bairro Fontana I - CEP, 45810-000, Bahia, Brazil.
  • Mota de Jesus R; State University of Santa Cruz, Department of Exact and Technological Sciences, Research Group in Analytical Chemistry of Southern Bahia, Rodovia Ilhéus-Itabuna, km 16, 45662-900 Ilhéus, Bahia, Brazil. Electronic address: rmota@uesc.br.
Food Chem ; 365: 130468, 2021 Dec 15.
Article em En | MEDLINE | ID: mdl-34392233
In this work, a method was developed for the determination of Na, K, Ca, Mg, P, S, Fe, Zn, Mn, and Cu by ICP OES and caffeine and epicatechin by HPLC-DAD in industrialized guarana-based beverages. The acid digestion in microwave oven was optimized by constrained mixture design. The optimum volumes found for the reagents were 2.60 mL (HNO3), 1.80 mL (H2O2), and 0.60 mL (HCl) for a final volume of 10 mL, resulting in a final digestate with residual acidity of 0.8 mol L-1 and 9% for residual carbon content. The detection limits found for the studied elements were between 0.0010 and 0.050 mg L-1. Precision (%RSD) was always below 6%. Accuracy was assessed by analyzing a certified reference material and addition and recovery tests. PCA and HCA were applied to caffeine, epicatechin and elemental concentrations aiming to evidence latent information.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Catequina / Paullinia Idioma: En Revista: Food Chem Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Catequina / Paullinia Idioma: En Revista: Food Chem Ano de publicação: 2021 Tipo de documento: Article País de afiliação: Brasil País de publicação: Reino Unido