Your browser doesn't support javascript.
loading
Assessment of frictional resistance and surface roughness in orthodontic wires coated with two different nanoparticles.
da Silveira, Ramiro Estacia; Elias, Carlos Nelson; do Amaral, Flávia Lucisano Botelho.
Afiliação
  • da Silveira RE; Faculdade São Leopoldo Mandic, Instituto de Pesquisas São Leopoldo Mandic, Campinas, Brazil.
  • Elias CN; Laboratório de Biomateriais, Instituto Militar de Engenharia, Rio de Janeiro, Brazil.
  • do Amaral FLB; Faculdade São Leopoldo Mandic, Instituto de Pesquisas São Leopoldo Mandic, Campinas, Brazil.
Microsc Res Tech ; 85(5): 1884-1890, 2022 May.
Article em En | MEDLINE | ID: mdl-34997799
Several mechanical and biological factors may change the orthodontic wire frictional resistance (FR). Titanium dioxide (TiO2 ) and silica dioxide (SiO2 ) nanoparticle (NP) coatings may be used to improve the characteristics of materials, reducing FR between archwire and bracket. This in vitro study aimed to evaluate the FR of orthodontic wires with and without coating in both dry and wet environments and measure the surface roughness (SR). One hundred and eighty segments of rectangular Cr-Ni orthodontic wires (Morelli Co, Brazil) were divided into three groups according to the NP coating applied: TiO2 group; SiO2 group; and control group. The SR parameters were measured in an optical profilometer, the surface morphology was analyzed with scanning electron microscopy (SEM), and FR was performed in a universal testing machine in dry and wet environments (n = 30). The statistical analysis was performed using the Generalized Estimated Equations model with a Bonferroni post-test (α = 0.05). It was observed that SiO2 NP coating decreased FR significantly when compared to the TiO2 and control groups, in both environments (p < .001). The SiO2 and TiO2 groups presented statistically lower SR than the control group and were similar to each other (p < .001). The SiO2 group presented the lower depth of Valley parameter than the TiO2 group (p < .001). The SEM showed that the TiO2 coating had the most heterogeneous surface morphology than the SiO2 and control groups. The orthodontic wires with NP coating modified the FR and morphology. The SiO2 coating reduced FR in both dry and wet environments and decreased SR. Titanium dioxide (TiO2 ) and silica dioxide (SiO2 ) nanoparticles coatings may be used to reduce frictional resistance (FR) between archwire and bracket as well as to improve surface morphology. The SiO2 coating reduced FR in both dry and wet environments and decreased the SR of Cr-Ni orthodontic wire. The TiO2 coating promoted the most heterogeneous surface morphology of Cr-Ni orthodontic wire.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Braquetes Ortodônticos / Nanopartículas Tipo de estudo: Prognostic_studies Idioma: En Revista: Microsc Res Tech Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Braquetes Ortodônticos / Nanopartículas Tipo de estudo: Prognostic_studies Idioma: En Revista: Microsc Res Tech Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos