Your browser doesn't support javascript.
loading
Postoperative intermittent dysfunction of mitral valve prosthesis of unclear etiology identified by three-dimensional echocardiography.
Cano-Nieto, Mariana M; Santibañez-Escobar, Felipe; Arias-Godinez, Jose A; Rodriguez-Zanella, Hugo G; Ortiz-Leon, Xochitl A; Ruiz-Esparza, Maria E; Fritche-Salazar, Juan F; Posada-Martinez, Edith L.
Afiliação
  • Cano-Nieto MM; Echocardiography Department, National Institute of Cardiology Ignacio Chavez, Tlalpan, Mexico, Mexico.
  • Santibañez-Escobar F; Surgery Department, National Institute of Cardiology Ignacio Chavez, Tlalpan, Mexico, Mexico.
  • Arias-Godinez JA; Echocardiography Department, National Institute of Cardiology Ignacio Chavez, Tlalpan, Mexico, Mexico.
  • Rodriguez-Zanella HG; Echocardiography Department, National Institute of Cardiology Ignacio Chavez, Tlalpan, Mexico, Mexico.
  • Ortiz-Leon XA; Echocardiography Department, National Institute of Cardiology Ignacio Chavez, Tlalpan, Mexico, Mexico.
  • Ruiz-Esparza ME; Echocardiography Department, National Institute of Cardiology Ignacio Chavez, Tlalpan, Mexico, Mexico.
  • Fritche-Salazar JF; Echocardiography Department, National Institute of Cardiology Ignacio Chavez, Tlalpan, Mexico, Mexico.
  • Posada-Martinez EL; Echocardiography Department, National Institute of Cardiology Ignacio Chavez, Tlalpan, Mexico, Mexico.
Echocardiography ; 39(4): 637-642, 2022 04.
Article em En | MEDLINE | ID: mdl-35277896
A 56-year-old patient with rheumatic heart disease and atrial fibrillation underwent mitral valve replacement with a mechanical prosthesis. The 3D perioperative echocardiogram showed an intermittent immobile medial disk without hemodynamic repercussion in the intensive care unit. The patient was taken back to the operating room and surgeons could not identify the cause. An enlarged left atrium and the size of the prosthetic valve was thought to have precipitated this condition. The heart team decided a biological prosthetic valve replacement would be performed. This case emphasizes the important role of the perioperative 3D echocardiogram in the detection of immediate surgical complications.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cardiopatia Reumática / Próteses Valvulares Cardíacas / Ecocardiografia Tridimensional / Implante de Prótese de Valva Cardíaca / Insuficiência da Valva Mitral / Estenose da Valva Mitral Tipo de estudo: Etiology_studies / Prognostic_studies Limite: Humans / Middle aged Idioma: En Revista: Echocardiography Assunto da revista: CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2022 Tipo de documento: Article País de afiliação: México País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cardiopatia Reumática / Próteses Valvulares Cardíacas / Ecocardiografia Tridimensional / Implante de Prótese de Valva Cardíaca / Insuficiência da Valva Mitral / Estenose da Valva Mitral Tipo de estudo: Etiology_studies / Prognostic_studies Limite: Humans / Middle aged Idioma: En Revista: Echocardiography Assunto da revista: CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2022 Tipo de documento: Article País de afiliação: México País de publicação: Estados Unidos