Your browser doesn't support javascript.
loading
Automatic audiometry using auditory steady-state response and sequential test strategy applied to volunteers with normal hearing.
Zanotelli, Tiago; Antunes, Felipe; Mendes, Eduardo Mazoni Andrade Marçal; Felix, Leonardo Bonato.
Afiliação
  • Zanotelli T; Federal Institute of Education Science and Technology of Espírito Santo, IFES, São Mateus Campus, Rodovia BR 101 Norte Km 58, Litorâneo, São Mateus, ES, 29932-540, Brazil. tiagoz@ifes.edu.br.
  • Antunes F; Federal Institute of Education Science and Technology of Minas Gerais, Ipatinga Campus, Ipatinga, MG, Brazil.
  • Mendes EMAM; Graduate Program in Electrical Engineering, Federal University of Minas Gerais, Belo Horizonte, MG, Brazil.
  • Felix LB; Department of Electrical Engineering, Federal University of Viçosa, Viçosa, MG, Brazil.
Eur Arch Otorhinolaryngol ; 279(12): 5885-5895, 2022 Dec.
Article em En | MEDLINE | ID: mdl-35763084
PURPOSE: In the present study, a new procedure to perform automatic audiometry using multifrequency Auditory Steady-State Response (ASSR) is proposed. METHODS: The automatic audiometry procedure consists of detecting the presence of multifrequency ASSR in real-time using the sequential test strategy and by adjusting the stimulus intensity independently. The ASSR audiometric thresholds of 18 adult volunteers with normal hearing were determined by automatically (four simultaneous frequencies per ear) at modulation frequencies in the 80 Hz range. The exam time and the difference between ASSR thresholds and pure-tone behavioural hearing thresholds were estimated as performance measures. RESULTS: The results showed that automatic audiometry can reduce the number of intensity levels used to obtain the ASSR threshold by up to 58% when compared to audiometry without using the techniques applied in automatic audiometry. In addition, the average of the difference between ASSR thresholds and Pure-Tone Behavioural Hearing thresholds was around 19 dB, which is similar to the results reported in similar studies. CONCLUSIONS: The audiometric procedure proposed in this study is fully automatic, i.e., does not require any human supervision throughout the exam, and is able to significantly reduce the conventional exam time.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Audiometria de Resposta Evocada / Audição Limite: Adult / Humans Idioma: En Revista: Eur Arch Otorhinolaryngol Assunto da revista: OTORRINOLARINGOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Audiometria de Resposta Evocada / Audição Limite: Adult / Humans Idioma: En Revista: Eur Arch Otorhinolaryngol Assunto da revista: OTORRINOLARINGOLOGIA Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil País de publicação: Alemanha