Your browser doesn't support javascript.
loading
Laboratory "In-vitro" Evaluation of the Parallel Stent Graft Association for the Iliac Sandwich Technique.
Franklin, Rafael Narciso; Timi, Jorge Rufino Ribas; Baumgardt, Guilherme; Bortoluzzi, Cristiano; Galego, Gilberto; Oderich, Gustavo S; Silveira, Pierre Galvagni.
Afiliação
  • Franklin RN; Coris Cirurgia Vascular e Endovascular, Rua Menino Deus, 63 sala 504, Baia Sul Medical Center, Centro, Florianópolis, SC, 88020-210, Brazil. rafael.n.franklin@coris.med.br.
  • Timi JRR; Universidade Federal de Santa Catarina, Florianópolis, SC, Brazil. rafael.n.franklin@coris.med.br.
  • Baumgardt G; Universidade Federal do Paraná, Curitiba, PR, Brazil.
  • Bortoluzzi C; The University of Texas Health Science Center at Houston, Houston, TX, USA.
  • Galego G; Coris Cirurgia Vascular e Endovascular, Rua Menino Deus, 63 sala 504, Baia Sul Medical Center, Centro, Florianópolis, SC, 88020-210, Brazil.
  • Oderich GS; Coris Cirurgia Vascular e Endovascular, Rua Menino Deus, 63 sala 504, Baia Sul Medical Center, Centro, Florianópolis, SC, 88020-210, Brazil.
  • Silveira PG; Universidade Federal de Santa Catarina, Florianópolis, SC, Brazil.
Cardiovasc Intervent Radiol ; 45(9): 1377-1384, 2022 Sep.
Article em En | MEDLINE | ID: mdl-35778578
OBJECTIVES: The Iliac Sandwich is an off-label technique that uses parallel stent grafts to treat aortoiliac aneurysms. The purpose of this experimental study is to evaluate the conformability and juxtaposition of stent grafts combinations used in this technique through in-vitro mechanical evaluation, computed tomography (CT) analyses, and a controlled pulsatile flow system. METHODS: The combinations of two Viabahn® ("V-V") or Viabahn® and Excluder® iliac extension ("V-E") were analysed using CT imaging with measurement of the gutter area by two independent analysts before and after balloon angioplasty. In a second phase, the parallel stent combinations were also evaluated using CT imaging after being implanted in the aortic aneurysm model with a pulsatile flow system with controlled temperature, viscosity, and density. RESULTS: The "V-E" group had a better conformability when compared to the "V-V" group, ensuring smaller gutter areas (0.0064 cm2 ± 0.01 vs. 0.0228 cm2 ± 0.03, p < 0.001). Post dilatation with two non-compliant balloons resulted in enlargement of the gutter area (Area A, p 0.065; Area B, p 0.071). Conversely, post dilatation with a non-compliant balloon for the internal iliac component and a compliant balloon for the external iliac device reduced the gutter area (Area A, p 0.008; Area B, p 0.010). CONCLUSION: The combination of Viabahn® and Excluder® iliac extension device ("V-E") had a smaller gutter area compared to two Viabahn® parallel stents for the Iliac Sandwich Technique. Post dilatation using a non-compliant balloon for the internal iliac device and a compliant balloon for the external iliac provided superior conformability and juxtaposition.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma Ilíaco / Aneurisma da Aorta Abdominal / Implante de Prótese Vascular / Procedimentos Endovasculares Tipo de estudo: Risk_factors_studies Limite: Humans Idioma: En Revista: Cardiovasc Intervent Radiol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma Ilíaco / Aneurisma da Aorta Abdominal / Implante de Prótese Vascular / Procedimentos Endovasculares Tipo de estudo: Risk_factors_studies Limite: Humans Idioma: En Revista: Cardiovasc Intervent Radiol Ano de publicação: 2022 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos