Your browser doesn't support javascript.
loading
An overview of automated flow systems for total and isotopic analysis of strontium and yttrium in samples of environmental interest.
Rodríguez-Maese, Rogelio; Cerdà, Víctor; Leal, Luz O.
Afiliação
  • Rodríguez-Maese R; Centro de Investigación en Materiales Avanzados, S.C. (CIMAV), Av. Miguel de Cervantes #120, Complejo Industrial Chihuahua, Chihuahua, Chih, C.P. 31136, Mexico.
  • Cerdà V; Department of Chemistry, University of the Balearic Islands, 07122, Palma de Mallorca, Spain; Sciware Systems, S.L. 07193, Bunyola, Spain. Electronic address: victorcerdamartin@gmail.com.
  • Leal LO; Centro de Investigación en Materiales Avanzados, S.C. (CIMAV), Av. Miguel de Cervantes #120, Complejo Industrial Chihuahua, Chihuahua, Chih, C.P. 31136, Mexico.
Talanta ; 270: 125643, 2024 Apr 01.
Article em En | MEDLINE | ID: mdl-38199120
ABSTRACT
Due to the different uses of radioactivity during the last decades, there has been an increase in the concentration of natural and artificial radionuclides in the environment. This, along with some accidents with a high affect public opinion (for example, Chernobyl and Fukushima), have led to the growth and establishment of environmental radioactivity monitoring programs. Currently, trends in legislation and research are focused on the development of accurate, precise, reliable and fast analytical methods with low limits of detection (LOD) for radionuclides determination, such as strontium and yttrium, in environmental samples. In this paper, two comprehensive reviews and four automated analytical systems for total and isotopic determination of yttrium and strontium are presented. The developed methods have been applied in the analysis of environmental samples with low concentrations of these analytes. These methodologies have been automated by exploiting flow analysis techniques, such as multi-syringe flow injection analysis (MSFIA), Sequential injection analysis (SIA) and laboratory-on-valve (LOV) systems, achieving a minimal handling and low consumption of samples and reagents, a significant reduction in waste generation and a high frequency of analysis. In the developed methodologies, some spectrometric methods such as ICP-OES and ICP-MS have been implemented as detection techniques instead of radiometric detectors obtaining a fully automated, low-cost and fast yttrium and strontium determinations.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Talanta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: México País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Talanta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: México País de publicação: Holanda