Your browser doesn't support javascript.
loading
Failures analysis of tube coating in Circulating Fluidized Bed (CFB) boiler.
Widjajanto, Teguh; Darmadi, Djarot B; Irawan, Yudy S; Gapsari, Femiana.
Afiliação
  • Widjajanto T; Department of Mechanical Engineering, Faculty of Engineering, University of Brawijaya, MT Haryono 167, Malang, 65145, Indonesia.
  • Darmadi DB; Department of Mechanical Engineering, Faculty of Engineering, University of Brawijaya, MT Haryono 167, Malang, 65145, Indonesia.
  • Irawan YS; Department of Mechanical Engineering, Faculty of Engineering, University of Brawijaya, MT Haryono 167, Malang, 65145, Indonesia.
  • Gapsari F; Department of Mechanical Engineering, Faculty of Engineering, University of Brawijaya, MT Haryono 167, Malang, 65145, Indonesia.
Heliyon ; 10(4): e26134, 2024 Feb 29.
Article em En | MEDLINE | ID: mdl-38379963
ABSTRACT
Circulating Fluidized Bed (CFB) boiler often experience leaks in the wall tube due to corrosion and abrasion of the bed material after use that varies between 3 and 8 months. To avoid erosion corrosion, a coating was done in the form of Chrome Clad Tube Armor (CTA). In this research, a Failure Analysis (FA) was performed on the characterization of the boiler tube using several types of samples, which are Wall Tube Without Coating (WT) and CTA (in new condition and after eight months of use). Macro visual, Field emission scanning electron microscopes (FE-SEM), Fourier-transform infrared spectroscopy (FTIR), corrosion, and Thermogravimetric analysis (TGA) tests showed that the CTA type has better corrosion and thermal resistance. The hardness values of the CTA and WT coating substrates after eight months of use were 197.75 and 195.2 HV. The failure mechanism on the tube was caused by high temperatures (long-term overheating) and friction between the tube and the fluid or metal. Wall tubes in furnaces fail due to erosion and corrosion due to fluid and solid particle mixtures and environmental contact.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Heliyon Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Indonésia País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Heliyon Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Indonésia País de publicação: Reino Unido