Your browser doesn't support javascript.
loading
Dual-luminophore pressure-sensitive paint measurement using three-gate lifetime method with photodegradation correction.
Uchida, Kazuki; Nakakita, Kazuyuki; Sugioka, Yosuke; Asai, Keisuke; Nonomura, Taku.
Afiliação
  • Uchida K; Department of Aerospace Engineering, Graduate School of Engineering, Tohoku University, 6-6-01 Aramaki-Aza-Aoba, Aoba-ku, Sendai, Miyagi 980-8579, Japan.
  • Nakakita K; Aviation Technology Directorate, Japan Aerospace Exploration Agency, 7-44-1 Jindaiji-Higashimachi, Chofu, Tokyo 182-0012, Japan.
  • Sugioka Y; Aviation Technology Directorate, Japan Aerospace Exploration Agency, 7-44-1 Jindaiji-Higashimachi, Chofu, Tokyo 182-0012, Japan.
  • Asai K; Department of Aerospace Engineering, Graduate School of Engineering, Tohoku University, 6-6-01 Aramaki-Aza-Aoba, Aoba-ku, Sendai, Miyagi 980-8579, Japan.
  • Nonomura T; Department of Aerospace Engineering, Graduate School of Engineering, Tohoku University, 6-6-01 Aramaki-Aza-Aoba, Aoba-ku, Sendai, Miyagi 980-8579, Japan.
Rev Sci Instrum ; 95(6)2024 Jun 01.
Article em En | MEDLINE | ID: mdl-38829218
ABSTRACT
In this paper, we propose a photodegradation correction method for the dual-luminophore pressure-sensitive paint (PSP) measurement using lifetime-based imaging, which was proposed for correction of the temperature-induced error but has suffered from photodegradation in the previous studies. We introduced a parameter that characterizes the photodegradation of a dual-luminophore PSP as the intensity ratio between the two luminophores. The changes in the calibration coefficients for the pressure and the temperature due to photodegradation were corrected based on this parameter. In this study, a coupon-based calibration test was performed, and the luminescence characteristics of the dual-luminophore PSP including photodegradation were investigated. Then, the proposed method was applied to a coupon-based validation test and a jet impingement test, and the effectiveness of the method was evaluated by comparing results with and without correction. The pressure measurement accuracy was significantly improved by photodegradation correction.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Rev Sci Instrum Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Japão País de publicação: Estados Unidos