CT imaging post-TAVI: Murphy's first law in action-preparing to recognize the unexpected.
Lisi, Costanza; Catapano, Federica; Brilli, Federica; Scialò, Vincenzo; Corghi, Eleonora; Figliozzi, Stefano; Cozzi, Ottavia Francesca; Monti, Lorenzo; Stefanini, Giulio Giuseppe; Francone, Marco.
Afiliação
  • Lisi C; Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Milan, Pieve Emanuele, Italy.
  • Catapano F; IRCCS Humanitas Research Hospital, via Manzoni 56, 20089, Milan, Rozzano, Italy.
  • Brilli F; Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Milan, Pieve Emanuele, Italy. federica.catapano@hunimed.eu.
  • Scialò V; IRCCS Humanitas Research Hospital, via Manzoni 56, 20089, Milan, Rozzano, Italy. federica.catapano@hunimed.eu.
  • Corghi E; Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Milan, Pieve Emanuele, Italy.
  • Figliozzi S; IRCCS Humanitas Research Hospital, via Manzoni 56, 20089, Milan, Rozzano, Italy.
  • Cozzi OF; Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Milan, Pieve Emanuele, Italy.
  • Monti L; IRCCS Humanitas Research Hospital, via Manzoni 56, 20089, Milan, Rozzano, Italy.
  • Stefanini GG; Department of Biomedical Sciences, Humanitas University, via Rita Levi Montalcini 4, 20090, Milan, Pieve Emanuele, Italy.
  • Francone M; IRCCS Humanitas Research Hospital, via Manzoni 56, 20089, Milan, Rozzano, Italy.
Insights Imaging ; 15(1): 157, 2024 Jun 20.
Article em En | MEDLINE | ID: mdl-38900378
ABSTRACT
Transfemoral aortic valve implantation (TAVI) has been long considered the standard of therapy for high-risk patients with severe aortic-stenosis and is now effectively employed in place of surgical aortic valve replacement also in intermediate-risk patients. The potential lasting consequences of minor complications, which might have limited impact on elderly patients, could be more noteworthy in the longer term when occurring in younger individuals. That's why a greater focus on early diagnosis, correct management, and prevention of post-procedural complications is key to achieve satisfactory results. ECG-triggered multidetector computed tomography angiography (CTA) is the mainstay imaging modality for pre-procedural planning of TAVI and is also used for post-interventional early detection of both acute and long-term complications. CTA allows detailed morphological analysis of the valve and its movement throughout the entire cardiac cycle. Moreover, stent position, coronary artery branches, and integrity of the aortic root can be precisely evaluated. Imaging reliability implies the correct technical setting of the computed tomography scan, knowledge of valve type, normal post-interventional findings, and awareness of classic and life-threatening complications after a TAVI procedure. This educational review discusses the main post-procedural complications of TAVI with a specific imaging focus, trying to clearly describe the technical aspects of CTA Imaging in post-TAVI and its clinical applications and challenges, with a final focus on future perspectives and emerging technologies. CRITICAL RELEVANCE STATEMENT This review undertakes an analysis of the role computed tomography angiography (CTA) plays in the assessment of post-TAVI complications. Highlighting the educational issues related to the topic, empowers radiologists to refine their clinical approach, contributing to enhanced patient care. KEY POINTS Prompt recognition of TAVI complications, ranging from value issues to death, is crucial. Adherence to recommended scanning protocols, and the optimization of tailored protocols, is essential. CTA is central in the diagnosis of TAVI complications and functions as a gatekeeper to treatment.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Insights Imaging Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Itália País de publicação: Alemanha