Your browser doesn't support javascript.
loading
Dual-Target Additively Manufactured Electrochemical Sensor for the Multiplexed Detection of Protein A29 and DNA of Human Monkeypox Virus.
Silva, Luiz Ricardo G; Stefano, Jéssica S; Kalinke, Cristiane; Crapnell, Robert D; Brazaca, Laís C; Marcolino-Junior, Luiz H; Bergamini, Marcio F; Banks, Craig E; Janegitz, Bruno C.
Afiliação
  • Silva LRG; Laboratory of Sensors, Nanomedicine and Nanostructured Materials, Federal University of São Carlos, Araras 13600-970, Brazil.
  • Stefano JS; Laboratory of Sensors, Nanomedicine and Nanostructured Materials, Federal University of São Carlos, Araras 13600-970, Brazil.
  • Kalinke C; Institute of Chemistry, University of Campinas (Unicamp), São Paulo 13083-859, Brazil.
  • Crapnell RD; Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, United Kingdom.
  • Brazaca LC; São Carlos Institute of Chemistry, University of São Paulo, São Carlos, SP 13083-970, Brazil.
  • Marcolino-Junior LH; Chemistry Department, Laboratory of Electrochemical Sensors (LabSensE), Federal University of Paraná, Curitiba, PR 81531-980, Brazil.
  • Bergamini MF; Chemistry Department, Laboratory of Electrochemical Sensors (LabSensE), Federal University of Paraná, Curitiba, PR 81531-980, Brazil.
  • Banks CE; Faculty of Science and Engineering, Manchester Metropolitan University, Chester Street, Manchester M1 5GD, United Kingdom.
  • Janegitz BC; Laboratory of Sensors, Nanomedicine and Nanostructured Materials, Federal University of São Carlos, Araras 13600-970, Brazil.
ACS Omega ; 9(30): 33099-33110, 2024 Jul 30.
Article em En | MEDLINE | ID: mdl-39100359
ABSTRACT
Herein, we present the first 3D-printed electrochemical portable biodevice for the detection of monkeypox virus (MKPV). The electrochemical device consists of two biosensors an immunosensor and a genosensor specifically designed for the detection of the protein A29 and a target DNA of MKPV, respectively. The electrodes were manufactured using lab-made ultraflexible conductive filaments composed of carbon black, recycled PLA from coffee pods, and castor oil as a plasticizer. The sensors created through 3D printing technology exhibited good reproducibility and repeatability of analytical responses. Furthermore, both the immunosensor and genosensor demonstrated excellent MKPV detection capabilities, with a linear range from 0.01 to 1.0 µmol L-1 for the antigen and 0.1 to 20.0 µmol L-1 for the DNA target. The biosensors achieved limits of detection of 2.7 and 29 nmol L-1 for the immunosensor and genosensor, respectively. Interference tests conducted with the biosensors demonstrated their selectivity for MKPV. Moreover, analyses of fortified human serum samples showed recoveries close to 100%, confirming the absence of significant matrix effects for MKPV analysis. Therefore, the 3D-printed multiplex device represents a viable and highly promising alternative for on-site, portable, and rapid point-of-care MKPV monitoring.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: ACS Omega Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: ACS Omega Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil País de publicação: Estados Unidos