Your browser doesn't support javascript.
loading
Meibography health score: a simple grading system for isotretinoin-induced meibography alterations on patients with acne vulgaris.
Andrade, Fabio Mendonça Xavier; Hirai, Flavio; Wakamatsu, Tais Hitomi; Medina, Rebecca Ignacio Subira; Freitas, Denise de.
Afiliação
  • Andrade FMX; Department of Ophthalmology and Visual Sciences, Hospital São Paulo, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
  • Hirai F; Department of Ophthalmology and Visual Sciences, Hospital São Paulo, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
  • Wakamatsu TH; Department of Ophthalmology and Visual Sciences, Hospital São Paulo, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
  • Medina RIS; Department of Dermatology, Hospital São Paulo, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
  • Freitas D; Department of Ophthalmology and Visual Sciences, Hospital São Paulo, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP, Brazil.
Arq Bras Oftalmol ; 88(1): e20230150, 2024.
Article em En | MEDLINE | ID: mdl-39109742
ABSTRACT

PURPOSE:

To develop a simple, subjective, and reliable grading scale for isotretinoin-induced meibography changes.

METHODS:

After analyzing meibography images obtained from systemic isotretinoin users, a grading scale was proposed and named "meibography health score." The score ranged from 1 to 3, with decreasing gland reflectivity and identifiable margins. A total of 11 medical professionals were asked to grade 10 meibography images obtained from isotretinoin users using the proposed scale and were divided into three groups (A) ophthalmologists with experience with meibography, (B) ophthalmologists with no experience with meibography, and (C) radiologists. The kappa statistic was determined to test interrater reliability.

RESULTS:

The overall kappa was approximately 0.64. The kappa scores for Groups A, B, and C were 0.78, 0.59, and 0.90, respectively. Grade 2 had the lowest kappa scores (0.62, 0.35, and 0.82 for A, B, and C, respectively) and grade 3 the highest (0.78, 0.90, and 1.0 for A, B and C, respectively). Furthermore, Group C had the highest kappa scores and Group B the lowest.

CONCLUSION:

The meibography health score exhibited good interrater reliability, particularly in severe cases.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Isotretinoína / Variações Dependentes do Observador / Acne Vulgar / Fármacos Dermatológicos / Glândulas Tarsais Limite: Female / Humans / Male Idioma: En Revista: Arq Bras Oftalmol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Isotretinoína / Variações Dependentes do Observador / Acne Vulgar / Fármacos Dermatológicos / Glândulas Tarsais Limite: Female / Humans / Male Idioma: En Revista: Arq Bras Oftalmol Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Brasil País de publicação: Brasil