Your browser doesn't support javascript.
loading
Clinical prediction nomogram for steroid-induced ocular hypertension risk in patients with intravitreal dexamethasone implant.
Cho, Won Jeong; Shin, Hye Jung; Kim, Min; Bae, Hyoung Won; Kim, Chan Yun; Choi, Wungrak.
Afiliação
  • Cho WJ; Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, South Korea.
  • Shin HJ; Biostatistics Collaboration Unit, Department of Biomedical Systems Informatics, Yonsei University College of Medicine, Seoul, South Korea.
  • Kim M; Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, South Korea.
  • Bae HW; Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, South Korea.
  • Kim CY; Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, South Korea.
  • Choi W; Institute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine, Seoul, South Korea.
Heliyon ; 10(14): e34635, 2024 Jul 30.
Article em En | MEDLINE | ID: mdl-39130483
ABSTRACT

Background:

Recognizing the risk factors and understanding the mechanisms underlying steroid-induced ocular hypertension (SIOH) are vital to prevent potent vision loss and ensure the safety and effectiveness of dexamethasone (DEX) injections. The study aimed to develop a novel nomogram for predicting the risk of SIOH and determining safety zones for steroid injections.

Methods:

This single-center, retrospective, case-control study included a total of 154 eyes with available measured axial length that had undergone AS-OCT and DEX implantation at the Yonsei University Health System. The eyes were categorized into the SIOH (n = 39) and post-steroid normal IOP (n = 115) groups. We measured intraocular pressure (IOP) for all eyes prior to DEX implantation, at 1 week post-implantation, and at 1, 2, 3, 6, and 12 months thereafter. We used AS-OCT to analyze the trabecular meshwork (TM) height and ocular parameters.

Results:

The predictive nomogram, including TM height, yielded an AUC of 0.807 (95 % confidence interval [CI], 0.737-0.877) and demonstrated significantly higher predictive accuracy than that of previous nomograms, which did not consider TM height and had an AUC of 0.644 (95 % CI, 0.543-0.745) (p = 0.031). The calibration plot demonstrated a strong predictive accuracy for a predicted value of approximately 0.4. We established cutoff values to ensure different levels of sensitivity and specificity within the safety zone following DEX implantation.

Conclusion:

Our improved nomogram incorporating TM height as a newly identified risk factor, established a safety threshold for intravitreal DEX implantation, helping identify safe individuals from those who require caution.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Heliyon Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Coréia do Sul País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Heliyon Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Coréia do Sul País de publicação: Reino Unido