Fully digitalized triple-energy x-ray computed tomography with high spatial resolutions using beam hardening.
Ito, Kazuki; Sato, Eiichi; Moriyama, Hodaka; Hagiwara, Osahiko; Enomoto, Toshiyuki; Yoshida, Sohei; Watanabe, Manabu.
Afiliação
  • Ito K; Department of Surgery, Toho University Ohashi Medical Center, 2-22-36 Ohashi, Meguro, Tokyo 153-8515, Japan.
  • Sato E; Department of Surgery, Toho University Ohashi Medical Center, 2-22-36 Ohashi, Meguro, Tokyo 153-8515, Japan.
  • Moriyama H; Honorary of Physics, Iwate Medical University, 2-14-6 Kawaramachi, Wakabayashi, Sendai, Miyagi 984-0816, Japan.
  • Hagiwara O; Department of Radiology, School of Medicine, Iwate Medical University, 2-1-1 Idaidori, Yahaba, Iwate 028-3694, Japan.
  • Enomoto T; Department of Surgery, Toho University Ohashi Medical Center, 2-22-36 Ohashi, Meguro, Tokyo 153-8515, Japan.
  • Yoshida S; Department of Surgery, Toho University Ohashi Medical Center, 2-22-36 Ohashi, Meguro, Tokyo 153-8515, Japan.
  • Watanabe M; Department of Surgery, Toho University Ohashi Medical Center, 2-22-36 Ohashi, Meguro, Tokyo 153-8515, Japan.
Rev Sci Instrum ; 95(8)2024 Aug 01.
Article em En | MEDLINE | ID: mdl-39140817
ABSTRACT
To regulate the effective photon energy with a constant tube voltage and to perform enhanced K-edge x-ray imaging, we built a prototype fully digitalized triple-energy x-ray computed tomography (TECT) scanner utilizing beam hardening. An object on the turntable is irradiated by a 0.1-mm-focus x-ray tube at 1.4-time-magnification. 720 raw radiograms are obtained using a flat panel detector, and 512 tomograms are reconstructed. With an increasing digital amplification factor, the gray raw-density projections obtained using low-energy-photon absorption disappeared at a constant maximum raw density, and the effective energy was increased by x-ray beam hardening. TECT was performed at digital amplifier factors below 3.0, and the effective energy increased with increasing amplification factors. In particular, fine blood vessels were visible using gadolinium-K-edge CT.