Predicting the Timing and Cause of Microvascular Free Flap Failure: An Australian Study of 1569 Free Flaps.
Gupta, Yash; Moisidis, Elias; Clarke, Fred; Haddad, Roger; Illie, Vlad; Southwell-Keely, James.
Afiliação
  • Clarke F; St Vincent's Department of Plastic and Reconstructive Surgery, Darlinghurst, NSW, Australia.
  • Haddad R; St Vincent's Department of Plastic and Reconstructive Surgery, Darlinghurst, NSW, Australia.
  • Illie V; St Vincent's Department of Plastic and Reconstructive Surgery, Darlinghurst, NSW, Australia.
Ann Plast Surg ; 93(4): 470-477, 2024 Oct 01.
Article em En | MEDLINE | ID: mdl-39150757
ABSTRACT

BACKGROUND:

The aim of the study is to assess the possible predictors of microvascular free flap failure and determine the critical postoperative timing of flap failure, thereby minimizing this adverse outcome.

METHODS:

This is a retrospective single-institutional review of 1569 free flap operations. All free flaps with outcome status recorded were analyzed for possible predictors in the development of microvascular compromise. Compromised cases were then analyzed for differences in time to compromise and time to theater takeback between salvaged versus failed free flaps.

RESULTS:

Of the assessable 1569 free flaps, 31 developed microvascular compromise (2.0%); the salvage rate was 20.0%, and overall failure rate was 1.5%. Osteocutaneous free flaps in head and neck had increased risk of developing free flap failure compared to other flaps (odds ratio = 3.8, 95% confidence interval 1.2-12.7). Among breast patients, previous radiotherapy had a significant association with flap failure ( P < 0.001). Free flap salvage rates dropped from 38.5% to 7.7% for compromises detected after 24 hours ( P = 0.160), and from 57.1% to 11.1% for free flaps taken back to theater greater than 3 hours after compromise detection ( P = 0.032).

CONCLUSIONS:

Delays in compromise detection and flap takeback to theater resulted in reduced salvage rates, with the critical timing of takeback being under 3 hours. Standardized flap monitoring protocols and incorporation of newer technologies could see faster detection and improved salvage rates. Additional care is required when reconstructing osteocutaneous head and neck free flaps and previously irradiated breast patients.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimentos de Cirurgia Plástica / Retalhos de Tecido Biológico Limite: Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: Oceania Idioma: En Revista: Ann Plast Surg / Ann. plast. sur / Annals of plastic surgery Ano de publicação: 2024 Tipo de documento: Article País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Procedimentos de Cirurgia Plástica / Retalhos de Tecido Biológico Limite: Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: Oceania Idioma: En Revista: Ann Plast Surg / Ann. plast. sur / Annals of plastic surgery Ano de publicação: 2024 Tipo de documento: Article País de publicação: Estados Unidos