Your browser doesn't support javascript.
loading
Extended ischemic times during ex vivo lung perfusion is not associated with increased mortality.
Gouchoe, Doug A; Satija, Divyaam; Cui, Ervin Y; Aly, Ahmed; Henn, Matthew C; Choi, Kukbin; Nunley, David; Mokadam, Nahush A; Ganapathi, Asvin M; Whitson, Bryan A.
Afiliação
  • Gouchoe DA; Division of Cardiac Surgery, Department of Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
  • Satija D; COPPER Laboratory, Department of Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
  • Cui EY; Division of Cardiac Surgery, Department of Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
  • Aly A; Division of Cardiac Surgery, Department of Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
  • Henn MC; COPPER Laboratory, Department of Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
  • Choi K; Division of Cardiac Surgery, Department of Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
  • Nunley D; Division of Cardiac Surgery, Department of Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
  • Mokadam NA; Division of Cardiac Surgery, Department of Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
  • Ganapathi AM; Division of Pulmonary, Allergy, Critical Care and Sleep Medicine, Department of Medicine, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
  • Whitson BA; Division of Cardiac Surgery, Department of Surgery, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
Artif Organs ; 2024 Aug 20.
Article em En | MEDLINE | ID: mdl-39165095
ABSTRACT

BACKGROUND:

The purpose of this study was to identify the association of increasing ischemic times in recipients who receive lungs evaluated by ex vivo lung perfusion (EVLP) and their association with outcomes following lung transplantation.

METHODS:

Lung transplant recipients who received an allograft evaluated by EVLP were identified from the United Network for Organ Sharing (UNOS) Database from 2016-2023. Recipients were stratified into three groups based on total ischemic time (TOT) short TOT (STOT, 0 to <7 h), medium TOT (MTOT, 7> to <14 h), and long TOT (LTOT, +14 h). The groups were assessed with comparative statistics and Kaplan-Meier methods. A Cox regression was created to determine the association of ischemic time in EVLP donors and long-term mortality.

RESULTS:

Recipients in the LTOT group had significantly longer length of stay and post-operative extracorporeal membrane use at 72 h (p < 0.05 for both). Additionally, they had nonsignificant increases in rate of stroke (4.7%, p = 0.05) and primary graft dysfunction grade 3 (PGD3, 27.5%, p = 0.082). However, there was no significant difference in hospital mortality or mid-term survival (p > 0.05 for both). On multivariable analysis, ischemic time was not associated with increased mortality whereas increasing recipient age, preoperative ECMO use and donation after circulatory death donors were (p < 0.05 for all).

CONCLUSIONS:

If EVLP technology is available, under certain circumstances, surgeons should not be dissuaded from using an allograft with extended ischemic time.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Artif Organs Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Artif Organs Ano de publicação: 2024 Tipo de documento: Article País de afiliação: Estados Unidos País de publicação: Estados Unidos