Your browser doesn't support javascript.
loading
Comparison of visual efficacy and patient's satisfaction between two toric IOLs, enhanced for intermediate vision and monofocal.
Hwang, Ho Sik; An, Dohyeon; Kim, Hyun Seung; Kim, Eun Chul.
Afiliação
  • Hwang HS; Department of Ophthalmology, Catholic University of Korea College of Medicine, Seoul, Korea.
  • An D; Department of Ophthalmology, Catholic University of Korea College of Medicine, Seoul, Korea.
  • Kim HS; Department of Ophthalmology, Catholic University of Korea College of Medicine, Seoul, Korea.
  • Kim EC; Department of Ophthalmology, Catholic University of Korea College of Medicine, Seoul, Korea. eunchol@hanmail.net.
BMC Ophthalmol ; 24(1): 378, 2024 Aug 27.
Article em En | MEDLINE | ID: mdl-39192181
ABSTRACT

BACKGROUND:

To compare the visual efficacy and patient satisfaction between 2 toric IOLs (TIOL), enhanced for intermediate vision or monofocal.

METHODS:

A retrospective chart review was performed of 100 eyes from 68 astigmatic patients who underwent cataract surgery with implantation of a Tecnis Eyhance Toric II IOL (Johnson & Johnson Vision, Irvine, CA, USA) (Group 1, 50 eyes) or Tecnis TIOL (Group 2, 50 eyes). The uncorrected distant (UDVA), intermediate (UIVA), and near (UNVA) visual acuities; residual refractive astigmatism; defocus curve; and IOL axis rotation were evaluated at 1 week, 1 month, 2 months, and 3 months postoperatively.

RESULTS:

The postoperative UDVA and UNVA refractive astigmatism values of the two groups were better than the preoperative measurements (P < 0.05), but there was no statistical difference between the two groups (P > 0.05). The postoperative UIVA of group 1 (0.18 ± 0.15 logMAR) was significantly better than that of group 2 (0.30 ± 0.25) (P < 0.05). The mean postoperative IOL rotation of group 1 (2.51 ± 0.79°) was lower than that of group 2 (3.02 ± 0.84°) (P < 0.05). Overall satisfaction of group 1 (1.27 ± 0.47) was better than that of group 2 (2.02 ± 0.53) (P < 0.05).

CONCLUSIONS:

The Tecnis Eyhance Toric II IOL demonstrated less postoperative IOL rotation and excellent uncorrected intermediate vision compared with the Tecnis TIOL. Near visual acuity and overall satisfaction with the Tecnis Eyhance Toric II IOL were also higher than those with the Tecnis TIOL.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desenho de Prótese / Astigmatismo / Acuidade Visual / Satisfação do Paciente / Implante de Lente Intraocular / Lentes Intraoculares Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Ophthalmol / BMC ophthalmol. (Online) / BMC ophthalmology (Online) Assunto da revista: OFTALMOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de publicação: Reino Unido

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desenho de Prótese / Astigmatismo / Acuidade Visual / Satisfação do Paciente / Implante de Lente Intraocular / Lentes Intraoculares Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: BMC Ophthalmol / BMC ophthalmol. (Online) / BMC ophthalmology (Online) Assunto da revista: OFTALMOLOGIA Ano de publicação: 2024 Tipo de documento: Article País de publicação: Reino Unido