Independent concentration extraction as a novel green approach resolving overlapped UV-Vis binary spectra and HPTLC-densitometric methods for concurrent determination of levocloperastine and chlorpheniramine.
Mohamed, Ekram H; Batakoushy, Hany A; Ibrahim, Adel Ehab; Nasr, Zeinab Adel; Soliman, Marwa M; Barghash, Sona S; Mohamed, Tahany F; Fouad, Fatma A.
Afiliação
  • Mohamed EH; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, The British University in Egypt, El Sherouk City, 11837, Egypt.
  • Batakoushy HA; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Menoufia University, Shebin Elkom, 32511, Egypt. hany.batakoushy@phrm.menofia.edu.eg.
  • Ibrahim AE; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Port-Said University, Port Said, 42511, Egypt.
  • Nasr ZA; Natural and Medical Sciences Research Center, University of Nizwa, Birkat Al Mauz, P.O. Box 33, Nizwa, 616, Oman.
  • Soliman MM; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy (Girls), Al-Azhar University, Cairo, 11754, Egypt. zeinabadel@azhar.edu.eg.
  • Barghash SS; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy (Girls), Al-Azhar University, Cairo, 11754, Egypt.
  • Mohamed TF; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy (Girls), Al-Azhar University, Cairo, 11754, Egypt.
  • Fouad FA; Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy (Girls), Al-Azhar University, Cairo, 11754, Egypt.
BMC Chem ; 18(1): 160, 2024 Aug 28.
Article em En | MEDLINE | ID: mdl-39198835
ABSTRACT

BACKGROUND:

The proposed research study introduces independent concentration extraction (ICE) as a novel UV-Vis spectrophotometric approach. The approach can be used for extracting the concentration of two analytes with severely overlapped spectra from their binary mixtures. ICE is based on spectral extraction platform involving simple smart successive methods that can directly extract the original zero order spectra of the analytes at their characteristic (λmax). Chlorpheniramine maleate (CPM) and Levocloperastine fendizoate (LCF) are two commonly co-formulated drugs in cough preparations. The combined mixture was used to confirm the validity of the developed ICE tool. Another less green HPTLC was developed for the first time to separate both drugs and help also in confirming the proposed tool.

METHODS:

For the simultaneous determination of CPM and LCF, two ecologically friendly techniques were employed. The first approach encompasses the use of the ICE spectrophotometric method that could be successively applied for extracting the concentration of two analytes with severely overlapped unresolved spectra in their binary mixtures. Other complementary methods aiming at original spectral extraction; including spectrum subtraction (SS) and unity subtraction (US) were also successfully employed to resolve the zero order spectra of the combined drugs with all their characteristic features and peaks. The second technique used, a high-performance TLC-densitometric one, was performed on silica plates with silica plates F254 and a mobile phase with a ratio of 3331 by volume of toluene, ethanol, acetone, and ammonia as a developing system at 230 nm.

RESULTS:

The presented extraction approach was executed without any optimization steps or sample pretreatment for the simultaneous determination of CPM and LCF. The method was found to be valid for their determination within concentration range of 3.0-30.0 µg mL-1 for both drugs. For HPTLC method, the resulting Rf values of CPM and LCF were 0.37 and 0.78, within concentration ranges of 0.3-4.0 µg/spot and 0.8-10.0 µg/spot, respectively. Greenness assessment of both developed methodologies showed that the HPTLC method is less green than the spectrophotometric method, yet with comparable sustainability when it comes to the used technique.

CONCLUSION:

The procedures were found to be selective, accurate, and precise for analysis of the studied binary mixture. Furthermore, the environmental impact of the introduced methods was assessed using novel greenness metrics, namely AGREE and Green Analytical Procedure Index (GAPI) to prove their ecological safety. In addition, white analytical chemistry (WAC) evaluation metric was employed to ensure the synergy and coherence of analytical, practical, and ecological attributes.