Your browser doesn't support javascript.
loading
Clinical Outcomes of Enhanced Monofocal (Mono-EDOF) Intraocular Lenses with the Mini-Monovision Technique versus Trifocal Intraocular Lenses: A Comparative Study
Can, Izzet; Bayhan, Hasan Ali.
Afiliação
  • Can I; Private Practice, Ankara, Türkiye.
  • Bayhan HA; Yozgat Bozok University Faculty of Medicine Ophthalmology Department, Yozgat, Türkiye.
Turk J Ophthalmol ; 54(4): 190-197, 2024 08 28.
Article em En | MEDLINE | ID: mdl-39205393
ABSTRACT

Objectives:

It was aimed to compare the clinical results of the mini-monovision technique (MMV) with enhanced monofocal intraocular lens (IOL) and trifocal IOL applications and to evaluate the intereye differences in the MMV group. Materials and

Methods:

This retrospective observational study evaluated the results of cataract surgeries performed on 48 eyes of 24 patients. Surgeries in Group I were performed for MMV using the RayOne EMV IOL targeting emmetropia in dominant eyes (Group IA) and -0.70 diopter (D) myopia in non-dominant eyes (Group IB), while those in Group II were performed with the AcrySof® IQ PanOptixTM TNFT00 IOL targeting emmetropia. After the surgeries, uncorrected and corrected distance, intermediate, and near distance visual acuities, contrast sensitivity measurements, and defocus curves were determined. Subjective evaluation was made with the National Eye Institute Visual Function Questionnaire (NEI VFQ-25). The groups were compared statistically.

Results:

Postoperative refraction mean spherical equivalent was -0.25±0.22 D, -0.67±0.33 D, and -0.16±0.31 D in the three groups, respectively. A statistical difference was identified in favor of Group IA for uncorrected distance vision and in favor of Group IB for near vision (p<0.05). There was no difference in bilateral uncorrected visions in Groups I and II (p>0.05). While contrast sensitivity was better in Group I at all spatial frequencies (p<0.05), better vision was achieved in the defocus curve at distance in Group IA and at near in Group IB. In the binocular evaluation, it was seen that Groups I and II had similar results. In the subjective evaluation, NEI-VFQ-25 scores were 94.1±4.2/100 in Group I and 91.5±3.0/100 in Group II at 6 months (p>0.05). Photic complaints were significantly more common in Group II.

Conclusion:

With the MMV technique, it was observed that enhanced monofocal lenses provided better visual acuity at all distances and less dysphotopsia than trifocal lenses, whereas trifocal lenses were better at providing independence from glasses.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desenho de Prótese / Refração Ocular / Acuidade Visual / Lentes Intraoculares Multifocais / Lentes Intraoculares Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Turk J Ophthalmol / Turk. J. Ophthalmol / Turkish journal of ophthalmology (online) Ano de publicação: 2024 Tipo de documento: Article País de publicação: Turquia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Desenho de Prótese / Refração Ocular / Acuidade Visual / Lentes Intraoculares Multifocais / Lentes Intraoculares Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Turk J Ophthalmol / Turk. J. Ophthalmol / Turkish journal of ophthalmology (online) Ano de publicação: 2024 Tipo de documento: Article País de publicação: Turquia