Your browser doesn't support javascript.
loading
Copper (II)-catalyzed polydopamine mediated photothermal sensors for visual quantitative point-of-care testing.
Zhang, Jingman; Luo, Yiying; Chen, Yiyu; Lian, Huiting; Liu, Bin; Chen, Chunnuan; Wei, Xiaofeng.
Afiliação
  • Zhang J; College of Materials Science and Engineering, Huaqiao University, Xiamen, 361021, China.
  • Luo Y; College of Materials Science and Engineering, Huaqiao University, Xiamen, 361021, China.
  • Chen Y; College of Materials Science and Engineering, Huaqiao University, Xiamen, 361021, China.
  • Lian H; College of Materials Science and Engineering, Huaqiao University, Xiamen, 361021, China.
  • Liu B; College of Materials Science and Engineering, Huaqiao University, Xiamen, 361021, China; Key Laboratory of Molecular Designing and Green Conversions, Huaqiao University, Xiamen, 361021, China; Xiamen Key Laboratory of Optoelectronic Materials and Advanced Manufacturing, Huaqiao University, Xiamen, 3
  • Chen C; Department of Neurology, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, 362000, China. Electronic address: chenchunnuan1983@aliyun.com.
  • Wei X; College of Materials Science and Engineering, Huaqiao University, Xiamen, 361021, China; Key Laboratory of Molecular Designing and Green Conversions, Huaqiao University, Xiamen, 361021, China; Xiamen Key Laboratory of Optoelectronic Materials and Advanced Manufacturing, Huaqiao University, Xiamen, 3
Anal Chim Acta ; 1325: 343114, 2024 Oct 09.
Article em En | MEDLINE | ID: mdl-39244302
ABSTRACT

BACKGROUND:

Temperature sensing is commonly used in point-of-care (POC) detection technologies, yet the portability and convenience of use are frequently compromised by the complexity of thermosensitive processes and signal transduction. Especially, multi-step target recognition reactions and temperature measurement in the reaction vessel present challenges in terms of stability and integration of detection devices. To further combine photothermal reaction and signal readout in one assay, these two processes enable to be integrated into miniaturized microfluidic chips, thereby facilitating photothermal sensing and achieving a simple visual temperature sensing as POC detection.

RESULTS:

A copper ion (Cu2+)-catalyzed photothermal sensing system integrated onto a microfluidic distance-based analytical device (µDAD), enabling the visual, portable, and sensitive quantitative detection of multiple targets, including ascorbic acid, glutathione, and alkaline phosphatase (ALP). The polydopamine nanoparticles (PDA NPs) were synthesized by the regulation of free Cu2+ through redox or coordination reactions, facilitating the transduction of distinct photothermal response signals and providing the versatile Cu2+-responsive sensing systems. Promoted by integration with a photothermal µDAD, the system combines PDA's photothermal responsiveness and thermosensitive gas production of ammonium bicarbonate for improved sensitivity of ALP detection, reaching the detection limit of 9.1 mU/L. The system has successfully achieved on-chip detection of ALP with superior anti-interference capability and recoveries ranging from 96.8 % to 104.7 %, alongside relative standard deviations below 8.0 %. SIGNIFICANCE AND NOVELTY The µDAD design accommodated both the photothermal reaction of PDA NPs and thermosensitive gas production reaction, achieving the rapid sensing of visual distance signals. The µDAD-based Cu2+-catalyzed photothermal sensing system holds substantial potential for applications in biochemical analysis and clinical diagnostics, underscored by the versatile Cu2+ regulation mechanism for a broad spectrum of biomarkers.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Ácido Ascórbico / Cobre / Testes Imediatos / Indóis Limite: Humans Idioma: En Revista: Anal Chim Acta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Ácido Ascórbico / Cobre / Testes Imediatos / Indóis Limite: Humans Idioma: En Revista: Anal Chim Acta Ano de publicação: 2024 Tipo de documento: Article País de afiliação: China País de publicação: Holanda