Use of a Fundus Image-Based Titration Strategy for Selective Retina Therapy for Central Serous Chorioretinopathy.
Jeon, Seung Hee; Kim, Minhee; Roh, Young-Jung.
Afiliação
  • Jeon SH; Department of Ophthalmology and Visual Science, Incheon St. Mary's Hospital, Catholic University of Korea, 56, Dongsu-ro, Bupyeong-gu, Incheon 21431, Republic of Korea.
  • Kim M; Department of Ophthalmology and Visual Science, Yeouido St. Mary's Hospital, Catholic University of Korea, 10, 63-ro, Yeongdeungpo-gu, Seoul 07345, Republic of Korea.
  • Roh YJ; Department of Ophthalmology and Visual Science, Yeouido St. Mary's Hospital, Catholic University of Korea, 10, 63-ro, Yeongdeungpo-gu, Seoul 07345, Republic of Korea.
J Clin Med ; 13(17)2024 Sep 04.
Article em En | MEDLINE | ID: mdl-39274443
ABSTRACT
Background/

Objectives:

This study evaluated the clinical outcomes of selective retina therapy (SRT) for treating central serous chorioretinopathy. A fundus image-based titration method was used for laser irradiation.

Methods:

This retrospective cohort study included 29 eyes (29 patients) that underwent SRT for CSC. Both the pulse energy and number of micropulses were adjusted according to the fundus image. Mean best-corrected visual acuity (BCVA), central foveal thickness (CFT), and subretinal fluid (SRF) height were measured 1, 2, 3, 4, and 6 months after SRT. Mean deviation (MD) was measured using microperimetry at 3 and 6 months post-treatment.

Results:

At 6 months after SRT treatment, SRF was completely resolved in 89.7% of cases (26/29 eyes). The mean Snellen BCVA significantly improved from 0.34 ± 0.31 logMAR (logarithm of the minimum angle of resolution) (20/40) at baseline to 0.24 ± 0.24 logMAR (20/32) at 6 months (p = 0.009). The 0.1 improvement in mean BCVA is equivalent to a 5-letter gain on the ETDRS chart. The mean CFT decreased significantly from 309.31 ± 81.6 µm at baseline to 211.07 ± 50.21 µm at 6 months (p < 0.001). The mean SRF height also decreased significantly from 138.36 ± 56.78 µm at baseline to 23.75 ± 61.19 µm at 6 months (p < 0.001). The mean MD was improved from -1.56 ± 1.47 dB at baseline to -1.03 ± 2.43 dB at 6 months (p = 0.07) after treatment.

Conclusions:

SRT using fundus image-based titration can yield favorable functional and anatomical outcomes in the treatment of CSC.