Your browser doesn't support javascript.
loading
BD Vacutainer™ Urine Culture & Sensitivity Preservative PLUS Plastic Tubes Minimize the Harmful Impact of Stressors Dependent on Temperature and Time Storage in Uropathogenic Bacteria.
Treviño, Samuel; Ramírez-Flores, Eduardo; Cortezano-Esteban, Steffany; Hernández-Fragoso, Hugo; Brambila, Eduardo.
Afiliação
  • Treviño S; Laboratory of Metabolomic and Chronic Degenerative Diseases, Physiology Institute, Meritorious Autonomous University of Puebla, Prol. de la 14 Sur 6301, Ciudad Universitaria, Puebla C.P. 72560, Mexico.
  • Ramírez-Flores E; Center for Care and Research in Health Services, Urinalysis and Microbiology Area, Rio Nexapa 6153, Col. San Manuel, Puebla C.P. 72560, Mexico.
  • Cortezano-Esteban S; Center for Care and Research in Health Services, Urinalysis and Microbiology Area, Rio Nexapa 6153, Col. San Manuel, Puebla C.P. 72560, Mexico.
  • Hernández-Fragoso H; Laboratory of Metabolomic and Chronic Degenerative Diseases, Physiology Institute, Meritorious Autonomous University of Puebla, Prol. de la 14 Sur 6301, Ciudad Universitaria, Puebla C.P. 72560, Mexico.
  • Brambila E; Laboratory of Chemical-Clinical Investigations, Department of Clinical Chemistry, Chemistry Department, Meritorious Autonomous University of Puebla, 14 Sur. FCQ1, Ciudad Universitaria, Puebla C.P. 72560, Mexico.
J Clin Med ; 13(17)2024 Sep 09.
Article em En | MEDLINE | ID: mdl-39274547
ABSTRACT

Background:

Urinary tract infection is a worldwide health problem. According to the Clinical Laboratory Improvement Amendments and the European Urinalysis Guideline, urine samples should be tested within 2 h of collection. Thus, using chemical preservatives that guarantee the pre-analytical conditions is a practical tool. However, the effects of temperature and storage time as uropathogenic bacteria stressors are unclear.

Methods:

Gram-negative and -positive ATTC strains, E. coli, P. mirabilis, E. faecalis, and S. aureus, were used in this study. Strains in liquid media were stored at 4, 25, and 37 °C for 0, 2, 12, 24, and 48 h in tubes with and without preservatives. Then, reactive oxygen species (ROS) levels, viable but non-culturable bacteria (VBNC), and bacteria growth were analyzed.

Results:

A high ROS level was associated with the presence of VBNC and dead bacteria with low CFU counts, but a low ROS level increased the CFU number, depending on temperature and storage time in tubes without preservatives (boric acid, sodium borate, and formate). The BD Vacutainer™ Urine Culture & Sensitivity Preservative PLUS Plastic Tubes (C&S-PP) prevent this ROS increase, maintaining the CFU number for longer.

Conclusions:

C&S-PP tubes minimize the stressor effects (temperature and time storage) on uropathogenic bacteria when stored, improving the pre-analytical conditions of cultures realized by the clinical laboratory.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Clin Med Ano de publicação: 2024 Tipo de documento: Article País de afiliação: México País de publicação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Clin Med Ano de publicação: 2024 Tipo de documento: Article País de afiliação: México País de publicação: Suíça