Este artigo é um Preprint
Preprints são relatos preliminares de pesquisa que não foram certificados pela revisão por pares. Eles não devem ser considerados para orientar a prática clínica ou comportamentos relacionados à saúde e não devem ser publicados na mídia como informação estabelecida.
Preprints publicados online permitem que os autores recebam feedback rápido, e toda a comunidade científica pode avaliar o trabalho independentemente e responder adequadamente. Estes comentários são publicados juntamente com os preprints para qualquer pessoa ler e servir como uma avaliação pós-publicação.
Performance verification of detecting COVID-19 specific antibody by using four chemiluminescence immunoassay systems
Preprint
em Inglês
| medRxiv
| ID: ppmedrxiv-20074849
ABSTRACT
BackgroundThe purpose of current study is to evaluate the analytical performance of seven kits for detecting IgM/IgG antibody of corona virus (2019-nCoV) by using four chemiluminescence immunoassay systems. Methods50 patients diagnosed with 2019-nCoV infection and 130 controls without corona virus infection from the General Hospital of Chongqing were enrolled in current retrospective study. Four chemiluminescence immunoassay systems including seven IgM/IgG antibody detection Kits for 2019-nCoV (A_IgM, A_IgG, B_IgM, B_IgG, C_IgM, C_IgG, D_Ab) were employed to detecting antibody concentration. Chi-square test, receiver operating characteristic (ROC) curve and Youdens index were demonstrated to verify the cutoff value of each detection system. ResultsThe repeatability verification results of the A, B, C, and D system are all qualified. D-Ab performances best (92% sensitivity and 99.23% specificity), and B_IgM worse than other systems. Except for the system of A_IgM and C_IgG, the optimal diagnostic thresholds and cutoff value of other kits from recommendations are inconsistent with each other. B_IgM got the worst AUC and C_IgG had the best diagnostic accuracy. More importantly, B_IgG system have the highest false positive rate for testing patients with AIDS, tumor and pregnant. A_IgM system test showed highest false positive rates among elder over 90 years old. ConclusionsSystems for CoVID-2019 IgM/IgG antibody test performance difference. Serum diagnosis kit of D-Ab is the most reliable detecting system for 2019-nCoV antibody, which can be used as an alternative method for nucleic acid testing.
cc_no
Texto completo:
Disponível
Coleções:
Preprints
Base de dados:
medRxiv
Tipo de estudo:
Estudo diagnóstico
/
Experimental_studies
/
Estudo observacional
Idioma:
Inglês
Ano de publicação:
2020
Tipo de documento:
Preprint