Your browser doesn't support javascript.
loading
Interobserver Agreement of Lung Ultrasound Findings of COVID-19
Andre Kumar; Yingjie Weng; Sally Graglia; Sukyung Chung; Youyou Duanmu; Farhan Lalani; Kavita Gandhi; Viveta Lobo; Trevor Jensen; John Kugler.
Afiliação
  • Andre Kumar; Stanford Unviersity
  • Yingjie Weng; Stanford University
  • Sally Graglia; University of California, San Francisco
  • Sukyung Chung; Stanford University School of Medicine
  • Youyou Duanmu; Stanford University School of Medicine
  • Farhan Lalani; University of California, San Francisco
  • Kavita Gandhi; University of California, San Francisco
  • Viveta Lobo; Stanford University School of Medicine
  • Trevor Jensen; University of California, San Francisco
  • John Kugler; Stanford University School of Medicine
Preprint em Inglês | medRxiv | ID: ppmedrxiv-20176156
ABSTRACT
BackgroundLung ultrasound (LUS) may be used in the diagnostic evaluation of patients with COVID-19. An abnormal LUS is associated with increased risk for ICU admission in COVID-19. Previously described LUS manifestations for COVID-19 include B-lines, consolidations, and pleural thickening. The interrater reliability (IRR) of these findings for COVID-19 is unknown. Research QuestionWhat is the interrater reliability of lung ultrasound findings in patients with RT-PCR confirmed COVID-19? Study Design and MethodsThis study was conducted at conducted at two academic medical centers between 03/2020-06/2020. Nine physicians (hospitalists n=4; emergency medicine n=5) independently evaluated n=20 LUS scans (n=180 independent observations) collected from RTPCR confirmed COVID-19 patients. These studies were randomly selected from an image database consisting of COVID-19 patients evaluated in the emergency department with portable ultrasound devices. Physicians were blinded to any patient information or previous LUS interpretation. Kappa values ({kappa}) were used to calculate IRR. ResultsThere was substantial IRR on the following items normal LUS scan ({kappa}=0.79 [95% CI 0.72-0.87]), presence of B-lines ({kappa}=0.79 [95% CI 0.72-0.87]), >=3 B-lines observed ({kappa}=0.72 [95% CI 0.64-0.79]). Moderate IRR was observed for the presence of any consolidation ({kappa}=0.57 [95% CI 0.50-0.64]), subpleural consolidation ({kappa}=0.49 [95% CI 0.42-0.56]), and presence of effusion ({kappa}=0.49 [95% CI 0.41-0.56]). Fair IRR was observed for pleural thickening ({kappa}=0.23 [95% CI 0.15-0.30]). InterpretationMany LUS manifestations for COVID-19 appear to have moderate to substantial IRR across providers from multiple specialties utilizing differing portable devices. The most reliable LUS findings with COVID-19 may include the presence/count of B-lines or determining if a scan is normal. Clinical protocols for LUS with COVID-19 may require additional observers for the confirmation of less reliable findings such as consolidations. Clinicaltrials.gov Registration NCT04384055 DisclosuresAndre Kumar, MD, MEd is a paid consultant for Vave Health, which manufactures one of the ultrasound devices used in this study. His consultant duties include providing feedback on product development. The other authors do not have any items to disclose.
Licença
cc_by_nc_nd
Texto completo: Disponível Coleções: Preprints Base de dados: medRxiv Tipo de estudo: Experimental_studies / Estudo observacional / Estudo prognóstico / Rct Idioma: Inglês Ano de publicação: 2020 Tipo de documento: Preprint
Texto completo: Disponível Coleções: Preprints Base de dados: medRxiv Tipo de estudo: Experimental_studies / Estudo observacional / Estudo prognóstico / Rct Idioma: Inglês Ano de publicação: 2020 Tipo de documento: Preprint
...