Comparison of two slide agglutination serotyping methods and PCR-based capsule typing for the characterization of Haemophilus influenzae serotypes
Braz. J. Microbiol.
; 37(1)2006.
Article
em En
| VETINDEX
| ID: vti-443941
Biblioteca responsável:
BR68.1
ABSTRACT
Ninety-three nasopharyngeal Haemophilus influenzae isolates were serotyped by two slide agglutination methods (SAST 1 and SAST 2) and the results compared with those obtained by capsule type-specific PCR. SAST 1 presented a low correlation with results obtained by PCR (75.2%) while SAST 2 showed a better agreement with the molecular technique results (93.5%). These findings suggest that SAST 2 could be an alternative method for adequate detection of H.influenzae type b.
RESUMO
Noventa e três isolados nasofaringeanos de H. influenzae foram sorotipados através de 2 métodos de aglutinação em lamina (SAST 1 e SAST 2) e os resultados foram comparados com a sorotipagem por PCR. SAST 1 apresentou uma baixa correlação com os resultados obtidos por PCR (75,2%) enquanto que SAST 2 mostrou uma melhor concordância com os resultados da técnica molecular (93,5%). Estes resultados indicam que SAST 2 pode ser um método alternativo para a correta detecção de H. influenzae tipo b.
Texto completo:
1
Base de dados:
VETINDEX
Idioma:
En
Revista:
Braz. J. Microbiol.
Ano de publicação:
2006
Tipo de documento:
Article