Analysis of temperature rise on the surface of buchanan plugger using thermocouple / 대한치과보존학회지
Journal of Korean Academy of Conservative Dentistry
; : 334-340, 2003.
Artigo
em Coreano
| WPRIM (Pacífico Ocidental)
| ID: wpr-111389
Biblioteca responsável:
WPRO
ABSTRACT
This study was performed to evaluate the actual temperature rise on the surface of Buchanan plugger using thermocouple. The heat carrier system 'System B Heatsource' (Model 1005, Analytic Technologies, Redmond, WA, USA) and the Buchanan pluggers of F, FM, M and ML sizes are used for this study. The temperature was set to 200degrees C on digital display and the power level on it was set to 10. Five thermocouples were placed in direct contact with the surface of each size of Buchanan's pluggers at 1 mm increments from the tip to the 4 mm length of shank. The heat control spring was touched for 5 seconds, and the temperature rise on the surface of the pluggers were measured at 1 sec intervals for more than 5 seconds with an accuracy of 0.01 using Data Logger. The data were statistically analyzed by one-way ANOVA. The results were as follows. 1. The position at which the temperature peaked was approximately at 1~2 mm far from the tip of Buchanan plugger (p<0.01). 2. The peak temperature was 215.25+/-2.28degrees C in F plugger, 185.94+/-2.19degrees C in FM plugger, 169.51+/-9.12degrees C in M plugger, and 160.79+/-1.27degrees C in ML plugger and the peak temperature was highest in F plugger and followed by, in descending order, FM plugger, M plugger. ML plugger showed the lowest peak temperature (p<0.01). 3. The temperature on the pluggers was decreased with the increase of touching time. This results suggest that the actual temperature on the surface of the pluggers does not correlate well with the temperature set on digital display. Heat concentrates around the tip. The larger plugger reveals lower temperature rise relatively.
Texto completo:
Disponível
Base de dados:
WPRIM (Pacífico Ocidental)
Assunto principal:
Temperatura Alta
Idioma:
Coreano
Revista:
Journal of Korean Academy of Conservative Dentistry
Ano de publicação:
2003
Tipo de documento:
Artigo