ABSTRACT
Several different viscoelastic substances are widely used in many ophthalmologic fields. In our study, the efficacy and safety of the different kinds of viscoelastics -Healon(R), Provisc(R), Viscorenal(R), Hyal-2000(R), Viscoat(R) and Biolon(R)-was evaluated in undergoing phacoemulsification and posterior intraocular lens implantation, corneal transplantation and ocular trauma surgery. We evaluated and the facility of the injection the foreign materials during injection of viscoelastics through the microscopy. We measured the changes of intraocular pressure at the postoperative 1 day and corneal endothelial cell count at the postoperative 2 month. The mean endothelial cell loss after phacoemulsification and posterior intraocular lens implantation was 13.71% at postoperative 1 day and there was no significantly different among groups. The incidence of the foreign materials including air bubles in viscoelastics in the operating microscope was Provisc(R), Hyal 2000 Viscorneal(R), Biolon(R), Healon(R) in order. The mean incidence of the intraocular pressure above 25 mmHg after cataract surgery at postoperative 1 day was 3.94%and was Hyal 2000(R), Biolon(R), Viscorneal(R), Healon(R), Provisc(R) in order. The incidence of the additional use of the antiglaucoma drugs in keratoplasty patients was 76%in Healon(R) group, 26.7%in Viscoat(R) group, 69.2%in Provisc(R) group respectively. From the results of this report, we conclude that it is desirable to use the proper viscoelastics according to the chemical and physical properties in special situations, but there is no significant difference in the same viscoelastic substance.
Assuntos

Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Catarata / Incidência / Transplante de Córnea / Facoemulsificação / Implante de Lente Intraocular / Células Endoteliais / Substâncias Viscoelásticas / Pressão Intraocular / Microscopia Tipo de estudo: Estudo de incidência / Estudo prognóstico Limite: Humanos Idioma: Coreano Revista: Journal of the Korean Ophthalmological Society Ano de publicação: 2000 Tipo de documento: Artigo
Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Catarata / Incidência / Transplante de Córnea / Facoemulsificação / Implante de Lente Intraocular / Células Endoteliais / Substâncias Viscoelásticas / Pressão Intraocular / Microscopia Tipo de estudo: Estudo de incidência / Estudo prognóstico Limite: Humanos Idioma: Coreano Revista: Journal of the Korean Ophthalmological Society Ano de publicação: 2000 Tipo de documento: Artigo
...