Central venous catheter malposition due to dialysis catheter: a case report / 대한마취과학회지
Korean Journal of Anesthesiology
; : 532-534, 2016.
Artigo
em Inglês
| WPRIM (Pacífico Ocidental)
| ID: wpr-123000
Biblioteca responsável:
WPRO
ABSTRACT
A 56-year-old man on maintenance hemodialysis was admitted to the intensive care unit with septic shock and coagulopathy. As there was a dialysis catheter in the right internal jugular vein, the left internal jugular vein was cannulated with a central venous catheter to initiate vasopressor therapy. A chest X-ray showed formation of a catheter loop inside the left brachiocephalic vein, probably due to hindrance by the dialysis catheter. This report describes the hurdles encountered, repeated cannulation attempts, and serial chest X-ray findings required to obtain acceptable placement of the catheter tip.
Texto completo:
Disponível
Base de dados:
WPRIM (Pacífico Ocidental)
Assunto principal:
Choque Séptico
/
Tórax
/
Cateterismo
/
Veias Braquiocefálicas
/
Diálise Renal
/
Diálise
/
Catéteres
/
Cateteres Venosos Centrais
/
Unidades de Terapia Intensiva
/
Veias Jugulares
Limite:
Humanos
Idioma:
Inglês
Revista:
Korean Journal of Anesthesiology
Ano de publicação:
2016
Tipo de documento:
Artigo