Cardiac Arrest during the Rotation of a Stainless Steel Bar in a Patient undergoing the Pectus Excavatum Repair : A case report
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-15982
Biblioteca responsável: WPRO
ABSTRACT
A 6-year-old-man with a severe pectus excavatum and marfanoid feature was admitted for the correction of pectus excavatum. Nuss procedure was recently introduced, because of its excellent effect from the cosmetic point of view. This method is that convex steel bar is inserted under the sternum through small bilateral thoracic incisions, and when it is in position, the bar is turn over, thereby correction the deformity. We experienced a case of the cardiac arrest during the rotation of a stainless steel bar. After the injection of atropine, epinephrine and the closed cardiac massage, sinus rhythm was restored. A vasovagal reflex due to the operation could be considered the possible etiology.
Assuntos

Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Reflexo / Atropina / Aço Inoxidável / Aço / Esterno / Anormalidades Congênitas / Epinefrina / Tórax em Funil / Parada Cardíaca / Massagem Cardíaca Limite: Humanos Idioma: Coreano Revista: Anesthesia and Pain Medicine Ano de publicação: 2007 Tipo de documento: Artigo
Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Reflexo / Atropina / Aço Inoxidável / Aço / Esterno / Anormalidades Congênitas / Epinefrina / Tórax em Funil / Parada Cardíaca / Massagem Cardíaca Limite: Humanos Idioma: Coreano Revista: Anesthesia and Pain Medicine Ano de publicação: 2007 Tipo de documento: Artigo
...