Recent Update on Microbiological Monitoring of Gastrointestinal Endoscopes after High-Level Disinfection
Clinical Endoscopy
; : 369-373, 2015.
Artigo
em Inglês
| WPRIM (Pacífico Ocidental)
| ID: wpr-170088
Biblioteca responsável:
WPRO
ABSTRACT
Endoscopy-related infections are important contributors to nosocomial infections. Endoscope reprocessing according to standard guidelines ensures high-level disinfection and prevents endoscopy-related infections. Microbiological surveillance may help in monitoring the effectiveness of gastrointestinal endoscope disinfection. The process involves microbial cultures and non-culture methods such as bioburden assays, adenosine triphosphate (ATP) bioluminescence, and quantitative polymerase chain reactions (PCRs). Surveillance culturing to monitor endoscopes after reprocessing has been recommended by a majority of organizations. Bioburden assays, ATP bioluminescence, and quantitative PCRs provide rapid and reliable measures. Each institution will have to try to establish its own surveillance guidelines.
Texto completo:
Disponível
Contexto em Saúde:
ODS3 - Saúde e Bem-Estar
Problema de saúde:
Meta 3.3: Acabar com as doenças tropicais negligenciadas e combater as doenças transmissíveis
Base de dados:
WPRIM (Pacífico Ocidental)
Assunto principal:
Trifosfato de Adenosina
/
Desinfecção
/
Reação em Cadeia da Polimerase
/
Infecção Hospitalar
/
Endoscópios
/
Endoscópios Gastrointestinais
Idioma:
Inglês
Revista:
Clinical Endoscopy
Ano de publicação:
2015
Tipo de documento:
Artigo