Fracture of the Humeral Shaft Secondary to High-Velocity Gunshot (Machine Gun) Injury: A Case Report
Artigo em Coreano | WPRIM (Pacífico Ocidental) | ID: wpr-180214
Biblioteca responsável: WPRO
ABSTRACT
High-velocity gunshot injury (muzzle velocity greater than 609.6 m/s) is uncommon and primarily a military injury. Humerus shaft fracture, caused by a high-velocity gunshot, should be considered as a severe open fracture. The principles of treatment are immediate and aggressive irrigation, wide debridement, primary delayed wound closure, and broad-spectrum intravenous antibiotics. External fixation has been widely used for fracture fixation. We report a case of humerus shaft fracture secondary to high-velocity gunshot (machine gun) injury, with a literature review.
Assuntos

Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Ferimentos e Lesões / Ferimentos por Arma de Fogo / Desbridamento / Fixação de Fratura / Fraturas Expostas / Úmero / Militares / Antibacterianos Limite: Humanos Idioma: Coreano Revista: Journal of the Korean Fracture Society Ano de publicação: 2017 Tipo de documento: Artigo
Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Ferimentos e Lesões / Ferimentos por Arma de Fogo / Desbridamento / Fixação de Fratura / Fraturas Expostas / Úmero / Militares / Antibacterianos Limite: Humanos Idioma: Coreano Revista: Journal of the Korean Fracture Society Ano de publicação: 2017 Tipo de documento: Artigo
...