Pyriform Sinus Perforation with Deep Neck Infection Caused by Transesophageal Echocardiography during Coronary Artery Bypass Grafting : A case report / 대한흉부외과학회지
The Korean Journal of Thoracic and Cardiovascular Surgery
; : 528-530, 2009.
Artigo
em Coreano
| WPRIM (Pacífico Ocidental)
| ID: wpr-209115
Biblioteca responsável:
WPRO
ABSTRACT
Transesophageal echocardiography (TEE) is widely used to evaluate the heart function and the result of surgery during a cardiac operation. The incidence of complications associated with TEE is low, yet critical complications such as lower pharyngeal injury and esophageal perforation may happen. We report here on a case of 77-year old male patient who suffered from injury to the pyriform sinus and concurrent deep neck infection after off pump coronary artery bypass surgery and intraoperative TEE
Texto completo:
Disponível
Base de dados:
WPRIM (Pacífico Ocidental)
Assunto principal:
Ecocardiografia
/
Ponte de Artéria Coronária
/
Incidência
/
Ecocardiografia Transesofagiana
/
Vasos Coronários
/
Ponte de Artéria Coronária sem Circulação Extracorpórea
/
Perfuração Esofágica
/
Seio Piriforme
/
Coração
/
Pescoço
Tipo de estudo:
Estudo de incidência
/
Estudo prognóstico
Limite:
Humanos
/
Masculino
Idioma:
Coreano
Revista:
The Korean Journal of Thoracic and Cardiovascular Surgery
Ano de publicação:
2009
Tipo de documento:
Artigo