Your browser doesn't support javascript.
loading
Percutaneous extraction of leads from coronary sinus vein and branch by modified techniques / 中华医学杂志(英文版)
Chinese Medical Journal ; (24): 3707-3711, 2012.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-256662
Biblioteca responsável: WPRO
ABSTRACT
<p><b>BACKGROUND</b>Cardiac resynchronization therapy (CRT) device and coronary sinus (CS) lead extraction are required due to the occurrence of systemic infection, malfunction, or upgrade. Relevant research of CS lead extraction is rare, especially in developing countries because of the high cost and lack of specialized tools. We aimed to evaluate percutaneous extraction of CS leads by modified conventional techniques.</p><p><b>METHODS</b>Of 200 patients referred for lead extraction from January 2007 to June 2011, 24 (12.0%) involved CS leads (24 CS leads). We prospectively analyzed clinical characteristics, optimized extraction techniques and feasibility of extraction.</p><p><b>RESULTS</b>Complete procedural success was achieved in 23 patients (95.8%), and the clinical success in 24 patients (100.0%). The leading indication for CS lead extraction was infection (66.7%). Mean implant duration was (29.5 ± 20.2) months (range, 3 - 78 months). Sixteen CS leads (66.6%) were removed with locking stylets plus manual traction by superior transvenous approach. Mechanical dilatation and counter-traction was required to free fibrotic adhesions and extract 4 CS leads (16.7%), which had longer implant duration than other leads ((62.5 ± 12.3) vs. (22.9 ± 14.1) months, P < 0.05). Another 4 CS (16.7%) leads were removed by modified and innovative snare techniques from femoral vein approach. Median extraction time was 11 minutes (range, 3 - 61 minutes) per CS lead, which had significant correlation with implant duration (r = 0.8, P < 0.001). Sixteen patients (66.6%) were reimplanted with new devices at a median of 7.5 days after extraction. Median followed-up was 23.5 months (range, 8 - 61 months), three patients died due to sudden cardiac death (26 months), heart failure (45 and 57 months, respectively).</p><p><b>CONCLUSION</b>The modified procedure was proved to be practical for percutaneous extraction of CS leads, especially in developing countries lacking expensive powered sheaths.</p>
Assuntos
Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Cirurgia Geral / Estudos Prospectivos / Remoção de Dispositivo / Eletrodos Implantados / Seio Coronário / Dispositivos de Terapia de Ressincronização Cardíaca / Métodos Tipo de estudo: Guia de prática clínica / Estudo observacional Limite: Idoso / Feminino / Humanos / Masculino Idioma: Inglês Revista: Chinese Medical Journal Ano de publicação: 2012 Tipo de documento: Artigo
Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Cirurgia Geral / Estudos Prospectivos / Remoção de Dispositivo / Eletrodos Implantados / Seio Coronário / Dispositivos de Terapia de Ressincronização Cardíaca / Métodos Tipo de estudo: Guia de prática clínica / Estudo observacional Limite: Idoso / Feminino / Humanos / Masculino Idioma: Inglês Revista: Chinese Medical Journal Ano de publicação: 2012 Tipo de documento: Artigo
...