Influence of active breathing control on the dose distribution in the target of forward whole-breast intensity-modulated radiotherapy after breast conserving surgery / 中华肿瘤杂志
Chinese Journal of Oncology ; (12): 617-621, 2009.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-295237
Biblioteca responsável: WPRO
ABSTRACT
<p><b>OBJECTIVE</b>To explore the influence of intrafraction and interfraction target displacement on the dose distribution in the target of forward whole-breast intensity-modulated radiotherapy (IMRT) assisted by active breathing control (ABC).</p><p><b>METHODS</b>Each of the selected patient who had received breast conserving surgery was immobilized and received the primary CT simulation assisted by ABC device to get five sets of CT images in three different breathing status, including free breathing (FB) (one set), moderate deep inspiration breathing hold (mDIBH)(two sets) and deep expiration breathing hold (DEBH) (2 sets). After 10 to 15 fractions of radiation, the repeated CT simulation was completed and the same five sets of CT images were obtained at FB, mDIBH, and DEBH, respectively. In the Pinnacle3 treatment planning system, the forward IMRT planning was completed on the first set of mDIBH CT images from the primary CT simulation, and the planning was separately copied by the special system order to the second set of CT images from the primary CT simulation and to the first set of CT images from the repeated CT simulation, keeping the primary angle, direction, size and shape of the MLC field and prescribed dose un-changed. the volumes covered by selected high dose area in the selected segment were compared.</p><p><b>RESULTS</b>In the planning based on the first set of mDIBH CT images from the primary CT simulation, the volume irradiated by equal and more than 103% of prescribed dose in the segment was (1.16 +/- 0.39) cm3, and the volumes were (3.88 +/- 1.07) cm3 and (51.66 +/- 8.68) cm3 in the plannings copied from the first set of mDIBH CT images from the primary CT simulation respectively to the second set of CT images from the primary CT simulation and first set of CT images from the repeat CT simulation, the difference of the volume in the two plannings based on the two set mDIBH CT image from the primary CT simulation was not statistically significant (t = -1.672, P = 0.103). The difference of the volume in the two plannings based on the two sets of mDIBH CT images respectively from the primary and repeat CT simulations had a significant difference (t = -5.728, P < 0.01).</p><p><b>CONCLUSION</b>If the same threshold of mDIBH is maintained during IMRT after breast conserving surgery, the influence of the intrafraction target displacement on the dose distribution is not significant. However, if set-up error is not adjusted, the interfraction change of position of the segment given to cover the high dose area in the IMRT planning will be significant, resulting in a significant change of dose distribution in the breast.</p>
Assuntos
Texto completo: Disponível Contexto em Saúde: ODS3 - Saúde e Bem-Estar Problema de saúde: Meta 3.4: Reduzir as mortes prematuras devido doenças não transmissíveis Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Período Pós-Operatório / Radioterapia / Respiração / Cirurgia Geral / Planejamento da Radioterapia Assistida por Computador / Neoplasias da Mama / Diagnóstico por Imagem / Radiografia / Mastectomia Segmentar / Carcinoma Lobular Tipo de estudo: Estudo diagnóstico Limite: Feminino / Humanos Idioma: Chinês Revista: Chinese Journal of Oncology Ano de publicação: 2009 Tipo de documento: Artigo
Texto completo: Disponível Contexto em Saúde: ODS3 - Saúde e Bem-Estar Problema de saúde: Meta 3.4: Reduzir as mortes prematuras devido doenças não transmissíveis Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Período Pós-Operatório / Radioterapia / Respiração / Cirurgia Geral / Planejamento da Radioterapia Assistida por Computador / Neoplasias da Mama / Diagnóstico por Imagem / Radiografia / Mastectomia Segmentar / Carcinoma Lobular Tipo de estudo: Estudo diagnóstico Limite: Feminino / Humanos Idioma: Chinês Revista: Chinese Journal of Oncology Ano de publicação: 2009 Tipo de documento: Artigo
...