Your browser doesn't support javascript.
loading
Evaluation of dosimetric variance in forward intensity modulated radiotherapy of the breast based on 4D CT and 3D CT during free breathing / 中华肿瘤杂志
Chinese Journal of Oncology ; (12): 759-763, 2012.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-307299
Biblioteca responsável: WPRO
ABSTRACT
<p><b>OBJECTIVE</b>To explore the dosimetric variance in forward intensity modulated radiotherapy (IMRT) based on 4D CT and 3D CT after breast conserving surgery.</p><p><b>METHODS</b>Seventeen patients after breast conserving surgery underwent 3D CT simulation scans followed by respiration-synchronized 4D CT simulation scans at free breathing state. The treatment plan constructed using the end inspiration (EI) scan was then copied and applied to the end expiration (EE), and 3D scans and dose distribution were calculated separately. Dose-volume histograms (DVHs) parameters for the CTV, PTV, ipsilateral lung and heart were evaluated and compared.</p><p><b>RESULTS</b>The CTV volume difference was biggest between T0 and 3D CT, and the volume difference was 4.10 cm(3). Mean dose of PTV at EE was lower than that at EI (P = 0.019), but there were no statistically significant difference between 3D and EI, EE (all P > 0.05). The homogeneity index (HI) at EI, EE, 3D plans were 0.149, 0.159 and 0.164, respectively, and a significant difference was only between EI and EE (P = 0.039). The highest conformal index (CI) was at EI phase (P < 0.05), and there was no significant difference between EE and 3D (P = 0.758). The V(40) and V(50) of ipsilateral lung at EE phase were lower than that at EI (P < 0.05). There were no significant differences in all the indexes for heart (P > 0.05).</p><p><b>CONCLUSIONS</b>The breast deformation during respiration may be disregarded in whole breast IMRT. PTV dose distribution is significantly changed between EI and EE phases, and the differentiation of the lung high dose area between EI and EE phases may be induced by thorax expansion. 3D treatment planning is sufficient for whole breast forward IMRT, but 4D CT scans assisted by respiratory gating ensures more precise delivery of radiation dose.</p>
Assuntos
Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Radioterapia / Dosagem Radioterapêutica / Respiração / Cirurgia Geral / Neoplasias da Mama / Diagnóstico por Imagem / Mastectomia Segmentar / Carcinoma Ductal de Mama / Adenocarcinoma Mucinoso / Fracionamento da Dose de Radiação Tipo de estudo: Estudo diagnóstico / Estudo de etiologia Limite: Adulto / Feminino / Humanos Idioma: Chinês Revista: Chinese Journal of Oncology Ano de publicação: 2012 Tipo de documento: Artigo
Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Radioterapia / Dosagem Radioterapêutica / Respiração / Cirurgia Geral / Neoplasias da Mama / Diagnóstico por Imagem / Mastectomia Segmentar / Carcinoma Ductal de Mama / Adenocarcinoma Mucinoso / Fracionamento da Dose de Radiação Tipo de estudo: Estudo diagnóstico / Estudo de etiologia Limite: Adulto / Feminino / Humanos Idioma: Chinês Revista: Chinese Journal of Oncology Ano de publicação: 2012 Tipo de documento: Artigo
...