Your browser doesn't support javascript.
loading
A comparison of clinical and angiographic outcomes after Excel bioabsorbable polymer versus Firebird durable polymer rapamycin-eluting stent for the treatment of coronary artery disease in a "real world" setting: six-month follow-up results / 中华医学杂志(英文版)
Chinese Medical Journal ; (24): 574-577, 2007.
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-344853
Biblioteca responsável: WPRO
ABSTRACT
<p><b>BACKGROUND</b>Several clinical trials have shown that rapamycin-eluting stents significantly reduce the risk of restenosis after percutaneous coronary intervention (PCI). The Firebird stent and the Excel stent (coated with bioabsorbable polymer) are two different types of rapamycin-eluting stents made in China, both have been recently approved for clinical use in China by State Food and Drug Administration. However, it is unclear whether there are differences in safety and efficacy between the two types of stents in daily practice.</p><p><b>METHODS</b>In the month of June 2006, a total of 190 consecutive patients were treated exclusively with Firebird stents (n = 93, Firebird group) or Excel stents (n = 97, Excel group) in our center and were included in this study. The frequency of major adverse cardiac events (MACE, a composite of death, myocardial infarction or target lesion revascularization), binary restenosis, and late lumen loss and stent thrombosis during a six-month follow-up period were compared between the two groups.</p><p><b>RESULTS</b>Patient and lesion characteristics were comparable between the groups. Major adverse cardiac event rates were low in hospital and at 6 months (2.1% in the Excel group and 0% in the Firebird group, P > 0.05). The 6-month angiographic in-stent restenosis rate was 0% in both groups, with an associated late loss of (0.15 +/- 0.21) mm versus (0.14 +/- 0.20) mm (P = 0.858) and the in-segment restenosis rate was also 0% for the Excel group and the Firebird group. There was no definite stent thrombosis identified in either group during the six-month follow-up period and only one patient in the Excel group had probable stent thrombosis in hospital.</p><p><b>CONCLUSIONS</b>Results from this mid-term, single-center study showed that both of the Firebird and the Excel rapamycin eluting stent had similar effects on reducing the incidence of MACE and the risk of restenosis (both in-stent and in-segment binary restenosis) after PCI in daily practice.</p>
Assuntos
Texto completo: Disponível Contexto em Saúde: ODS3 - Meta 3.4 Reduzir as mortes prematuras devido doenças não transmissíveis Problema de saúde: Doença Cardiovascular / Doença Isquêmica do Coração Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Polímeros / Angioplastia Coronária com Balão / Stents / Seguimentos / Sistemas de Liberação de Medicamentos / Angiografia Coronária / Sirolimo / Reestenose Coronária / Métodos Tipo de estudo: Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Inglês Revista: Chinese Medical Journal Ano de publicação: 2007 Tipo de documento: Artigo
Texto completo: Disponível Contexto em Saúde: ODS3 - Meta 3.4 Reduzir as mortes prematuras devido doenças não transmissíveis Problema de saúde: Doença Cardiovascular / Doença Isquêmica do Coração Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Polímeros / Angioplastia Coronária com Balão / Stents / Seguimentos / Sistemas de Liberação de Medicamentos / Angiografia Coronária / Sirolimo / Reestenose Coronária / Métodos Tipo de estudo: Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Adulto / Idoso / Feminino / Humanos / Masculino Idioma: Inglês Revista: Chinese Medical Journal Ano de publicação: 2007 Tipo de documento: Artigo
...