Your browser doesn't support javascript.
loading
A Case of Complete Thrombotic Occlusion by Endovascular Stent Grafting for Anastomosis Leakage after Aortic Arch Replacement of Stanford Type A Dissecting Aortic Aneurysm / 日本心臓血管外科学会雑誌
Artigo em Japonês | WPRIM (Pacífico Ocidental) | ID: wpr-366499
Biblioteca responsável: WPRO
ABSTRACT
A 60-year-old woman with acute Stanford type A dissecting aneurysm underwent Dacron graft replacement of the total aortic arch combined with the modified elephant trunk technique. Follow-up CT and angiogram demonstrated blood flow into the false lumen from the distal anastomosis. In order to interrupt the blood flow, endovascular stent grafting was undertaken. She recovered uneventfully, and was discharged on the 14th postoperative day. Follow-up CT taken in the third postoperative month demonstrated exclusion of the blood flow into the false lumen of descending thoracic aorta. Aortic arch replacement followed by endovascular stent grafting of the descending thoracic component is a potential therapeutic option in patients with dissecting aneurysm.

Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Idioma: Japonês Revista: Japanese Journal of Cardiovascular Surgery Ano de publicação: 1999 Tipo de documento: Artigo
Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Idioma: Japonês Revista: Japanese Journal of Cardiovascular Surgery Ano de publicação: 1999 Tipo de documento: Artigo
...