Your browser doesn't support javascript.
loading
The experimental study on dual-energy imaging for the diagnosis of acute pulmonary embolism using dual-source CT / 中华放射学杂志
Chinese Journal of Radiology ; (12): 651-655, 2009.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-394364
Biblioteca responsável: WPRO
ABSTRACT
Objective To evaluate the feasibility and value of dual-energy perfusion imaging (DEPI) of dual-source CT(DSCT) in the diagnosis of acute experimental pulmonary embolism. Methods Acute pulmonary embolism ( PE ) model was made in 8 New Zealand rabbits, and non-enhanced and enhanced DSCT scans were performed before and after embelization. Postprocessing of image data was made on the workstation, and CT pulmonary angiography ( CTPA ), DEal and fusion images were obtained. The location and number of the emboli were recorded. The rabbits were killed immediately after DSCT scan, the location and number of the lung lobes with pulmonary emboli were evaluated pathologically. Based on the pathological results, the sensitivity, specificity, positive predictive value ( PPV), and negative predictive value (NPV) of CTA, DEal and fusion images for the diagnosis of PE were calculated. Weighted Kappa values were calculated to evaluate the consistency between CTPA and DEal. Results PE model was made successfully in 7 rabbits. Six rabbits with 30 lobes were evaluated with one exception because of the catheter affecting the quality of lung peffusian image. PE was found pathologically in 18 lobar arteries. On DEPI, the region with PE showed low peffusion area comparing with the normal parenchyma and CTPA showed the filling defect within corresponding pulmonary artery or interruption of the artery. The sensitivity, specificity, PPVand NPV of CTPA were 66. 7% (12/18), 100.0% (12/12), 100.0% (12/12) and 66. 7% (12/18), respectively. The Kappa value was 0. 651 indicating moderate correlation with pathology. The sensitivity, specificity, aPv, and NPV of DEal were 88. 9% ( 16/18), 91.7% ( 11/12, 94. 1% (16/17) and 84. 6% ( 11/13 ), respectively. The Kappa value was 0. 795 indicating excellent correlation with pathology. Conclusion Dual-energy lung perfusion imaging of DSCT can display the blood distribution of rabbit's lung and has a high sensitivity for the diagnosis of acute pulmonary embolism.

Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Idioma: Chinês Revista: Chinese Journal of Radiology Ano de publicação: 2009 Tipo de documento: Artigo
Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Tipo de estudo: Estudo diagnóstico / Estudo prognóstico Idioma: Chinês Revista: Chinese Journal of Radiology Ano de publicação: 2009 Tipo de documento: Artigo
...