ABSTRACT
Objective To evaluate operative methods and the clinical effect of closed reduction and percuta-neous locking compression titanium plate internal fixation in treatment of distal tibial fractures.Methods The clinical data of 21 patients with fracture who received closed reduction technology through the subcutaneous tunnel of fracture end,minimally invasive percutaneous treatment of tibial locking titanium plate fixation were retrospectively analyzed. Results All 21 patients were followed up from 6 to 18 months(11 months in average).All patients recovered with good healing of fracture.According to criteria of Johner -Wruhs score,the results were excellent in 12 cases,good in 6 cases,fair in 3 cases,and poor in 0 case.The excellent and good rate was 85.71%.Conclusion The method of closed reduction and percutaneous locking compression titanium plate internal fixation in treatment of distal tibial frac-tures can protect skin soft tissue,reduce the damage to the blood -supply of the fracture,promote the healing of the fracture and reduce complications.

Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Primary Medicine and Pharmacy Ano de publicação: 2016 Tipo de documento: Artigo