Your browser doesn't support javascript.
loading
Clinical Observation of Autoserum Eye Drops in the Treatment of Filamentosa Keratitis after Excimer Laser Corneal Refractive Surgery / 中国药房
China Pharmacy ; (12): 4121-4123, 2015.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-502714
Biblioteca responsável: WPRO
ABSTRACT

OBJECTIVE:

To observe clinical efficacy and safety of Autoserum eye drops in the treatment of filamentary kerati-tis after excimer laser corneal refractive surgery.

METHODS:

46 patients (90 eyes) with filamentary keratitis after excimer laser corneal refractive surgery were selected and randomly divided into control group and observation group with 23 cases(45 eyes)in each group. The control group was given clearing mesh+wearing soft contact lens+bFGF eye drops;the observation group was giv-en clearing mesh+ wearing soft contact lens + Autoserum eye drops. The clinical efficacy,cure time,recurrence rate and ADR were compared between 2 groups.

RESULTS:

The total effective rate of observation group was 93.3%,which was higher than that (82.2%)of the control group,with statistical significance(P0.05).

CONCLUSIONS:

In the treatment of filamentous keratitis after excimer laser corneal refractive surgery,therapy of clearing mesh+wearing soft contact lens+Autoserum eye drops have high total effective rate,low recurrence rate and short cure period with less ADR.

Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: China Pharmacy Ano de publicação: 2015 Tipo de documento: Artigo