Your browser doesn't support javascript.
loading
Determination of the Content of Dehydroepiandrosterone in Dehydroepiandrosterone Tablets by HPLC / 中国药房
China Pharmacy ; (12)1991.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-518905
Biblioteca responsável: WPRO
ABSTRACT

OBJECTIVE:

HPLC method was established for the determination of dehydroepiandrosterone(DHEA)in tablets.

METHODS:

The chromatographic system consisted of ?-Bondapak C18 column and mobile phase of methanol-water(75∶25)with a detection wavelength at 292nm.

RESULTS:

The linear range of DHEA was 0.2~1.0mg/ml,r=0.9 999.The recovery rate was 99.13%(RSD=0.42%).

CONCLUSION:

This method is simple and accurate for determination of DHEA in tablets.

Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: China Pharmacy Ano de publicação: 1991 Tipo de documento: Artigo
Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: China Pharmacy Ano de publicação: 1991 Tipo de documento: Artigo
...