Method for Determination of Bisphenol A in Drinking Water by Liquid Chromatography-Tandem Mass Spectrometry / 环境与健康杂志
Journal of Environment and Health
; (12)1992.
Artigo
em Chinês
| WPRIM (Pacífico Ocidental)
| ID: wpr-548439
Biblioteca responsável:
WPRO
ABSTRACT
Objective To develop a rapid and sensitive method for the determination of bisphenol A in drinking water by liquid chromatography-electrospray tandem mass spectrometry. Methods Bisphenol A was extracted from the drinking water sample by a SEP-PAK C18 column,eluted with methanol and concentrated with a rotary evaporator. The extract was analyzed by liquid chromatography-tandem mass spectrometry with electrospray ionization. Results The calibration curve of bisphenol A was linear in the range of 5 -100 ng/ml,the linear equation was y =6 796.61x -8 655.64 and the correlation coefficients of linear calibration curve was 0.999 2. The limit of detection (S/N=3) and the limit of quantification (S/N=10) of bisphenol A were 0.007 5 ng/ml and 0.025 ng/ml,respectively. The rates of recovery of bisphenol A were from 83.46% to 94.00% and the relative standard deviation was 3.06% -4.60%. Conclusion The method is simple,rapid,accurate and is applicable to the qualitative and quantitative determination of bisphenol A in drinking water.
Texto completo:
Disponível
Base de dados:
WPRIM (Pacífico Ocidental)
Tipo de estudo:
Pesquisa qualitativa
Idioma:
Chinês
Revista:
Journal of Environment and Health
Ano de publicação:
1992
Tipo de documento:
Artigo