Treatmant of no-reflow phenomenon during percutaneous coronary intervention / 中国介入心脏病学杂志
Chinese Journal of Interventional Cardiology
; (4)2003.
Artigo
em Chinês
| WPRIM (Pacífico Ocidental)
| ID: wpr-585601
Biblioteca responsável:
WPRO
ABSTRACT
Objective To evaluate the effect of injecting UK and Herbesser into the target coronary artery where no-reflow happened during percutaneous coronary intervention. Methods Among the 820 acute coronary syndrome (ACS) patients who underwent PCI from Jan. 1990 to Apr. 2004, no-reflow phenomenon occurred in 86 patients. Three hundred cases with acute myocardial infraction (AMI) underwent primary PCI, no-reflow phenomenon occurred in 50 cases. In the other 520 unstable angina pectoris (UAP) cases, no-reflow phenomenon occurred in 36 cases during PCI. All the 86 patients with no-reflow were given intra-coronary arteries nitroglycerin but 78 of them showed no improvement in coronary perfusion and were in turns devided into 3 groups randomly. Group A (n=26) was given intra-vessel UK and Herbesser alternately. The maximan dosage of UK was 2?105 U kIU and 2 mg for Herbesser. Group B (n=24) was given intra-coronary Herbesser 500 ?g each time until the maximum amount reached 2 mg. Group C (n=28) was given UK which maximun dosage was 2?105 U. Results All the 26 cases in Group A showed significant improvement in blood flow (P
Texto completo:
Disponível
Base de dados:
WPRIM (Pacífico Ocidental)
Idioma:
Chinês
Revista:
Chinese Journal of Interventional Cardiology
Ano de publicação:
2003
Tipo de documento:
Artigo