Your browser doesn't support javascript.
loading
Significance of Hemoglobin Detection Test Kit Using in Hospital Supply Center / 中华医院感染学杂志
Article em Zh | WPRIM | ID: wpr-594663
Biblioteca responsável: WPRO
ABSTRACT
OBJECTIVE To compare the difference of testing cleaning effectiveness in the operation instrument between the eye measurement and hemoglobin enzyme test.METHODS Five batches of instrument after cleaning were tested by two methods.RESULTS By eye inspection,all tested samples were qualified.However there were only 76 percent of samples qualified according to enzyme test.CONCLUSIONS Compared with eye inspection,enzyme test is a more sensitive method.Enzyme test can better assess the cleaning effectiveness than others.
Palavras-chave
Texto completo: 1 Base de dados: WPRIM Tipo de estudo: Diagnostic_studies Idioma: Zh Revista: Chinese Journal of Nosocomiology Ano de publicação: 2006 Tipo de documento: Article