Your browser doesn't support javascript.
loading
Application value of percutaneous puncture biopsy technique under CT guide in clinical ;pathological changes of breast / 中国医学装备
China Medical Equipment ; (12): 67-69,70, 2016.
Artigo em Chinês | WPRIM (Pacífico Ocidental) | ID: wpr-604314
Biblioteca responsável: WPRO
ABSTRACT

Objective:

To evaluate the diagnosis value of percutaneous puncture biopsy technique under CT guiding in clinical pathological changes of breast.

Methods:

46 patients with breast lumps or nodules, including six cases of pleural disease, were carried out percutaneous puncture biopsy under CT guide, where a coaxial Angiotech 17G trocar together with BiopincelSG were used in the puncture process.

Results:

44 cases of pathological findings were acquired and the diagnosis ratio was 93.4%, including 9 cases of squamous cell carcinoma, 24 cases of adenocarcinoma, 3 cases of small cell carcinoma, 1 case of metastatic tumor, 1 case of tuberculosis cases, 5 cases of inflammation and 1 case of normal reflexed pleura. 2 cases have no clear diagnosis.

Conclusion:

The percutaneous lung biopsy technique under CT guide has the merits of less diagnosis trauma, high diagnosis accuracy and high clinical application value.

Texto completo: Disponível Contexto em Saúde: Doenças Negligenciadas Problema de saúde: Tuberculose Base de dados: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: China Medical Equipment Ano de publicação: 2016 Tipo de documento: Artigo
Texto completo: Disponível Contexto em Saúde: Doenças Negligenciadas Problema de saúde: Tuberculose Base de dados: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: China Medical Equipment Ano de publicação: 2016 Tipo de documento: Artigo
...