ABSTRACT

Objective:

To compare inverse three-dimensional conformal radiotherapy (Inv 3D-CRT) and intensity modulated ra-diotherapy (IMRT) for non-small cell lung cancer.

Methods:

For a cohort of 10 patients, Inv 3D-CRT and three groups of IMRT plannings were designed for per patient. The prescribed dose was 60 Gy/2 Gy/30f, 95% of the planning target volume received this dose. Dose was computed with a commercially available TPS using convolution/superposition (CS) algorithm. Plans were compared according to the PTV_(95)V_(20) ratio (PTV_(95)V_(20)) and D_(max)-D_(min).

Results:

Compared with Inv 3D-CRT, the PTV_(95)V_(20) ratio of three groups of IMRT increased by 1.08 (P = 0.014), 0.72 (P = 0.089) and 0.42 (P = 0.318), respectively.

Conclusions:

For NSCLC, IMRT can reduce the dose to the lungs compared with inverse 3D-CRT by improving the conformity of the plan and is worth spreading in clinical work.

Texto completo: Disponível Base de dados: WPRIM (Pacífico Ocidental) Idioma: Chinês Revista: Chinese Journal of Medical Physics Ano de publicação: 2010 Tipo de documento: Artigo