Agreement on keratometry readings and computed IOL power using Haigis and SRK/T formulas between ray tracing (iTrace®) and partial coherence interferometry (IOLMaster®) among patients in an outpatient surgical center
Artigo em Inglês | WPRIM (Pacífico Ocidental) | ID: wpr-633168
Biblioteca responsável: WPRO
ABSTRACT
@#<p style="text-align justify;"><strong>

OBJECTIVE:

</strong> To determine if there is an agreement between keratometry readings and intraocular lens (IOL) power calculation using Haigis and Sanders, Retzlaff and Kraff theoretical (SRK/T) formulas obtained by iTrace® and IOLMaster®.</p> <p style="text-align justify;"><strong>

METHODS:

</strong> A retrospective chart review of patients who underwent preoperative biometry using both IOLMaster® and iTrace® from January 2015 to July 2015 and satisfied the inclusion/exclusion criteria were included in the study. The average keratometry, cylinder power and predicted IOL power were computed accordingly. Agreement between devices was analyzed using Bland Altman.</p> <p style="text-align justify;"><strong>

RESULTS:

</strong> A total of 70 eyes from 35 study participants were included in the analysis. The means of average keratometry values obtained from IOLMaster® and iTrace® were 43.9 ± 1.3 D and 43.6 ± 1.3 D respectively. The paired mean differences in the average keratometry and cylinder power between instruments were -0.3 ± 0.3 and 0.1 ± 0.4 respectively. There was a statistically significant difference in the proportion between the number of times there will be a need to change IOL power and the number of times IOL power will remain the same using the Haigis formula with a p value of <0.0005.</p> <p style="text-align justify;"><strong>

CONCLUSION:

</strong> Average keratometry values, cylinder power and IOL calculation using the Haigis formula obtained by the two devices tested did not show agreement. There is agreement using the SRK/T formula. </p>
Assuntos
Buscar no Google
Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Estudos Retrospectivos / Biometria / Córnea / Lentes Intraoculares Tipo de estudo: Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Adulto / Feminino / Humanos / Masculino Idioma: Inglês Revista: Philippine Journal of Ophthalmology Ano de publicação: 2016 Tipo de documento: Artigo
Buscar no Google
Base de dados: WPRIM (Pacífico Ocidental) Assunto principal: Estudos Retrospectivos / Biometria / Córnea / Lentes Intraoculares Tipo de estudo: Estudo observacional / Estudo prognóstico / Fatores de risco Limite: Adulto / Feminino / Humanos / Masculino Idioma: Inglês Revista: Philippine Journal of Ophthalmology Ano de publicação: 2016 Tipo de documento: Artigo
...