Effects of microwave on the contents of MDA and SOD in renal cortex and testis of mice / 军事医学科学院院刊
Bulletin of The Academy of Military Medical Sciences
; (6): 24-26, 2001.
Artigo
em Chinês
| WPRIM (Pacífico Ocidental)
| ID: wpr-643043
Biblioteca responsável:
WPRO
ABSTRACT
Objective:
To observe the effects of microwave on the activity of SOD and the contents of MDA in renal cortex and testis of mice.Methods:
Microwave generator(2 450 MHz, 10 mW/cm2) was used to expose mice; NBT,DTNB and TBA were used to mearure the activity of SOD and the contents of MDA in renal cortex and testis of the mice after microwave exposure.Results:
The content of MDA in renal cortex and testis of the mice increased progressively on days 1,6,12 and reached the highest level on day 24 after the microwave exposure (P<0.01). The activity of SOD in renal cortex and testis of the mice decreased progressively on days 1, 6, 12 and reached the lowest level on day 24 after the microwave exposure (P<0.01).Conclusions:
Microwave exposure can produce reactive oxygen free radicals and lead to depress SOD activity.
Texto completo:
Disponível
Base de dados:
WPRIM (Pacífico Ocidental)
Idioma:
Chinês
Revista:
Bulletin of The Academy of Military Medical Sciences
Ano de publicação:
2001
Tipo de documento:
Artigo