Objective To establish the analytical method of oleandrin and adynerin in human blood by HPLC-MS/MS. Methods After protein sediment by acetonitril, the concentrations of oleandrin and adynerin in human blood were quantitatively determined by HPLC-MS/MS. The qualitative analysis was conducted based on retention time and MRM ions. Besides, the standard curve method was used for quantification. Results The detection limits of both oleandrin and adynerin were 0.5ng/mL, the linear range was from 1ng/mL to 1mg/mL, with a recovery rate of 75.2%~95.7%. Conclusion The detecting protocol has the advantages of high sensitivity, fast and high accuracy with a relatively wide linear range, which is especially suitable for rapid detection of oleander toxins, alexandrine and adynerin in particular, in human blood in poisoning cases.
Palavras-chave
Texto completo: 1 Base de dados: WPRIM Tipo de estudo: Diagnostic_studies / Qualitative_research Idioma: Zh Revista: Chinese Journal of Forensic Medicine Ano de publicação: 2017 Tipo de documento: Article